93
5.2
Monitor the parameter list
number
instruction
dn-00
Monitor display options (the default for motor speed), and by setting the Pn079 parameter, make the
dn -
00 show different monitoring status.
dn-01
Speed instruction (r/min)
dn-02
The average torque (%)
dn-03
Position deviation value (9999 ~ 9999) (unit: a)
dn-04
The ac power voltage (V)
dn-05
The maximum instantaneous torque (%)
dn-06
Input pulse frequency (in KHZ)
dn-07
Heat sink temperature (
℃
)
dn-08
The current motor speed (r/min)
dn-09
Effective input command pulse accumulative total value low (9999 ~ 9999) (unit: a)
dn-10
Effective input command pulse accumulative total value high (5000 ~
5000) (unit: m) (pulse accumulative total value high more than + 5000, the h
igh position 0, low today, to count)
dn-11
Effective feedback position control, the encoder pulse accumulative total value is low (9999 ~ 9999) (unit: a)
dn-12
Effective feedback position control, the encoder
pulse accumulative total value high (5000 ~ 5000) (unit: m) (feedback pulse accumulative total value
more than + 5000 high, high position 0, low today, to count)
dn-13
Regenerative braking load factor
dn-14
Signal input port state, from left to right in turn is SigIn1 ~ SigIn4 (1: high level; 0: low level)
dn-15
Output port status signal, from left to right in turn is SigOut1 ~ SigOut4 (1: high level; 0: low level)
dn-16
Analog torque command voltage (V)
dn-17
Simulation speed reference voltage (V)
dn-18
Output function status register