73
number
name
value
range
the
default value
unit
apply
Pn128
Internal position
command zero speed
0~3000
100
r/min
P
Pn129
Internal position
command
1
speed
0~3000
100
r/min
Pn130
Internal position
command 2
speed
0~3000
100
r/min
P
Pn131
Internal position
command 3
speed
0~3000
100
r/min
P
◢
When performing internal position instruction N, restrict the highest speed of motor can run.
number
name
value range
the
default value
unit
apply
Pn132
Torque/speed control switch to
the position control
0~1
0
P
◢
Control mode from the speed/torque mode conversion to position control
(Pn002 = 3 or 4), to avoid severe mechanical shock, should be in low speed switching.
The conditions of the switch can be set up:
Pn132=0
:
zerospeed
)
Pn132=1
:
Slow down to zero
number
name
value range
the
default value
unit
apply
Pn133
Torque/speed control
switch to the position control of the
deceleration time
5-10000
100
ms
P
◢
Pn132 = 1, when cmode signals effectively, the order control