94
dn-19
After power on the servo, motor feedback pulse accumulative total value low (9999 ~ 9999) (unit: a)
dn-20
Electric servo, motor feedback pulse accumulative
total value high (5000 ~ 5000) (unit: m) (feedback pulse accumulative total value more than + 5000
high, high position 0, low today, to count)
dn-21
The drive software version
dn-22
Encoder UVW signals from left to right in order for the sale of state level (1: high level; 0: low level)
dn-23
Rotor absolute position
Note: Dn -
18 output function status register
SigOut port state of logic, namely each Bit position shown in the table below:
Bit
Bit7 Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
function
Run
Zero Speed
Treach
Sreach
Preach
Emg
Ready
Alarm
Bit
Bit15 Bit14
Bit13
Bit12
Bit11
Bit10
Bit9
Bit8
function
-
-
-
SPL
TRQL
Pnear
HOME
BRK
Function for Bit is 0, said ON state, 1 is the OFF state.
Chapter 6 alarm and processing
6.1
Alarm
clearance operations
As shown
in the third chapter of the auxiliary model operation "police clearance operation"
6.2
Alarm content and countermeasure
Alarm display
Clear way
Abnormal alarm instructions
Elimination method
AL-01
power on
The memory
chip memory contents are
To initialize the parameters, and observation.
Internal