10
●
Cable length, instruction cable within 3 m, encoder cable within 20 m
●
Check the L1, L2, L3 power wiring is correct
or not, please do not connect to
the 380 v power supply.
●
U, V, W terminal phase sequence, must be corresponded
to the terminal correspondence of the motor,
otherwise, the motor
may not transfer or coaster,
the motor may not transfer or coaster.
Can't use exchange
three-phase terminal method to make motor reversal, this is totally different with
asynchronous motor
●
must be reliable grounding, and single point grounding
●
into the output signal of the relay, the absorption of the direction of the diode to connected
correctly, otherwise it will cause failure cannot output signal
●
in order to prevent noise caused by the wrong action, please add in power transformer and
noise filter device in the same wiring tube
●
please install the fuse type
circuit breaker that drive failure can promptly cut off the external power supply
2.1.3
Wire specifications
terminals
wire specifications
Power cord
U、V、
0.75
~
2.5mm²
Motor terminals
0.75
~
2.5mm²
Earthing terminal terminal
0.75
~
2.5mm²
control symbol
CN2
≥
0.12
mm²(AWG26), Including shielded
Encoder signal
CN3
≥
0.12
mm²(AWG26), Including shielded
Encoder cable must use twisted-pair cable. If the encoder cable is
label