internal
90
Position deviation to
clear
parameters:
Pn108
way
0
During the Pclear level ON
1
Pclear rise along time (from OFF to ON)
20
INH
Pulse input is prohibited
OFF:
Pulse allows input instructions
ON :
Input instruction pulse have been banned, ignored
21
PC
Proportional control
OFF:
Speed loop PI control
ON :
Speed loop P control
22
GOH
The
23
REF
The origin return
reference point
24
Pos1
Pos1 internal
location choice
25
Pos2
Pos2
internal
location choice
26
ptriger
Trigger
position command
27
pstop
Suspend internal
position command
4.4.2 SigOut
SigOut port function explanation
number
symbol
function
Functional specifications
0
null
No function specified
1
Alarm
Alarm detection
OFF: alarm
ON: no alarm