69
Positioning to complete set
◢
While the rest of the deviation counter pulse number is lower than the parameters setting, output port
SigOut Preach signal is ON, or OFF.
number
name
value range
the
default value
unit
apply
Pn106
Position location close to the
range of Settings
0~ 32767
300
P
Pn107
Position location close to the
poor set
back
0~ 32767
30
P
◢
While the rest of the deviation counter pulse number is lower than the parameters setting, output port
SigOut Pnear signal is ON, or OFF.
编号
number
name
value range
the
default value
unit
apply
Pn108
Position deviation clear way
0-1
1
P
◢
Position control, can use SigIn Pclear function, clear position deviation value of the counter.
Position deviation clearance
in -
0: Pclear level ON period
1: Pclear rise along time (from OFF to ON)
number
name
value range
the
default value
unit
apply
Pn109
◆
Position command deceleration mode
0-2
1
P
◢
0
Do not use the filter
◢
1
A smoothing filter
◢
2
S-shaped filtering
number
name
value range
the
default value
unit
apply
Pn110
◆
Position command s-shaped
5~1750
50
ms
P
Pulse
Pulse