58
The motor running
top speed limit
◢
Used to restrict the highest speed of the motor running. Value should be less than or equal to the rated
speed,
otherwise the motor can run a maximum speed of the rated speed
number
name
value range
the
default value
unit
apply
Pn052
▲
SigIn1 port functional allocation
-27~27
1
All
Pn053
▲
SigIn2port functional allocation
-27~27
2
All
Pn054
▲
SigIn3
port functional allocation
-27~27
19
All
Pn055
▲
SigIn4 port functional allocation
-27~27
8
All
◢
1
:
Specific functional allocation reference SigIn function, a table
◢
2
:
-
1 ~ 27 function number is 1-27 corresponding negative logic function, function is the same, the effective level instead
Parameter
values
SigIn input level
SigIn corresponding function
positive values
low level
ON
high level
OFF
negative
low level
OFF
high level
ON
◢
3
If the same overlapped functions assigned to different port, the port number of ports real effective, small
number of port doesn't work. Example: SigIn1 -
> 6; SigIn -
> 3-6; The functions assigned to SigIn 3, 6
and logic is negative, and SigIn 1 port status is ignored
number
name
value range
the
default value
unit
apply
Pn056
SigIn filtering time 1 port
1~1000
2
ms
All
Pn057
SigIn filtering time 2
port
1~1000
2
ms
All