63
ban pulse command, set Pn071 BIT4 set 0, input pulse becomes invalid. The communication control,
set the parameter value, shall be invalid.
Note: after each access to electricity,
drive will automatically load the Pn070, Pn071 register values, and perform the corresponding
operation immediately. So, before enabling the motor to determine the function of input signal into
the proper working condition
number
name
value range
the
default value
unit
apply
Pn074
Fan temperature
30~70
50
℃
All
Pn075
Fan operation mode
0~2
0
All
◢
Fan operation mode are: 0: heat automatically
1
boot operation
2:
don't run
number
name
value
range
the
default value
unit
apply
Pn076
Emergency stop reset (EMG)
0-1
0
All
◢
Lift its state of EMG OFF after the removal of EMG (AL -
14) alarm conditions:
0
Must be under the servo can make OFF, by manual or port SigIn: AlarmRst cleared.
1
Regardless of servo enabled ON or OFF, EMG again into ON, will be automatically removed
◢
In can make ON the state, if the external command input, EMG alarm automatically remove, instructions are executed immediately
number
name
value range
the
default value
unit
apply
Pn077
Is/the driving ban checked out
0-2
0
All
◢
If use the function of CCWL or.cwl, when CCWL or.cwl for the OFF state, whether can be set up from AL
-
15 police
0
Don't send out alarm
1
Motor is running, reducing stopped, send out alarm, motor is no longer current
2
Immediately issued a warning, motor power, free downtime