AB phase logic
◢
0: motor counterclockwise A, B in advance. Clockwise ahead of A B
◢
1: motor counterclockwise B ahead; Clockwise ahead of B
number
name
value range
the
default value
unit
apply
Pn019
▲
Rated current Settings
0-15
0
A
All
Pn020
▲
Rated speed setting
0~5000
Rated speed
r/min
All
◢
Parameter is set to 0, use the manufacturer to set a default value; Otherwise, the user must be strictly in
accordance with the motor rated current RMS, rated speed and the corresponding internal positive and
negative torque limit setting parameter values.
If set incorrectly, the motor will not be able to run properly.
According to the code of different types and motor drive, can achieve the largest actual current value is
different. Please do not modify the average user.
number
name
value range
the
default value
unit
apply
Pn021
reach to
predetermined speed
0~5000
500
r/min
All
Pn022
Hysteresis comparison
difference in predetermined
speed
0~5000
30
r/min
All
Pn023
Reach to
predetermined
speed detection direction
0-2
0
All
◢
When the motor is running at a faster rate than the decision value set, the output port SigOut Sreach will turn
ON, or to OFF.
◢