88
torque limit
ON:
Note: whether TCCW efficient or effective, CCW
direction torque is also restricted by Pn008 parameters.
6
TCW
Around outside the
torque limit
OFF:
The CW direction torque Pn011 parameters without limit
ON:
The CW direction torque Pn011 parameter restrictions
Note: whether TCW efficient or effective, the CW
direction torque is also restricted by Pn009 parameters.
7
EMG
Emergency stop
OFF:
Ban drive motor drive, to cut off the motor current
ON:
Allow normal drive motor drive
8
Zero
Lock
Zero speed clamp
Speed control:
OFF:
Don't lock the motor shaft
ON :
Lock the motor shaft
9
SP1
Internal speed
command option 1
When a drive control mode in
speed control mode, the speed reference source by SigIn SP1,
SP2, SP3 decision:
SP3
SP2
SP1
Speed instruction
0
0
0
internal speed
1 /
External analog
External analog
0
0
1
internal speed
2
0
1
0
internal speed
3
0
1
1
internal speed
4
1
0
0
internal speed
5
1
0
1
internal speed
6
1
1
0
internal speed
7
1
1
1
internal speed
8
Note:0 means OFF,1means ON.
Note 2: if the SigIn port is not specified SP3, SP2,
10
SP2
Internal speed
command option 2
11
SP3
3 nternal speed
command option 1
The CCW Direction torque Pn010 parameters restrictions