26
motor. Drive at a speed loop model, running speed by buttons
▲
or ▼
input. In the process of the motor running, the other menu operations can
be performed. If the motor stop rotating, please enter Jog_2 mode
2
Exit speed control mode, the motor is power
off
Note: if the display
or
, the possible reasons are as follows:
1
The motor is in the state of enabling
or rotating. JOG trial run before operation, the motor must be in a non
-working state.
when commissioning,the control interface of the servo drive don’t be connected to any control lines.
2
Servo driver alarm has occurred, and the alarm is not cleared.
3.4.5 Fn003 Alarm
clearance operations
{
MODE
MODE
清除成功
清除失败
MODE
▲
▼
长按
,
释放
SET
MODE
长按
,
释放
SET
MODE
Note:When the clearance is failure at last,display
,the Checked
out
alarm can be cleared only after power on again
Through the clear operation to clear the alarm
Electricity can remove alarm again
AL--02
Low voltage
AL--01
Storage anomaly
AL--05
Overload 1
AL--03
overvoltage