81
1
1
1
Internal speed 8
Note 1:0
is
OFF, 1 is
ON.
Note 2: if the SigIn port is not specified SP3, SP2, SP1 function, is OFF by default
number
name
value
range
the
default value
unit
apply
Pn177
speed
0~5000
200
r/min
S
Pn178
◆
speed up the time
5~ 10000
100
ms
S
Pn179
◆
Deceleration time
5~ 10000
100
ms
S
◢
When commissioning at, can set the speed of the motor running and the deceleration time
4.3.4
Torque control parameters
number
name
value range
the
default value
unit
apply
Pn186
Torque command deceleration mode
0~1
0
T
◢
0:
Do not use the deceleration torque instruction
◢
1
Using linear deceleration torque instruction
number
name
value range
the
default value
unit
apply
Pn187
▲
Linear deceleration time constant torque instruction
1~30000
1
ms
T
◢
Time constant is defined as a torque command from zero has soared to the rated torque.
Pn187
Rated Torque
Time