Smartports
Configuring Smartport Using The Web-based Interface
Cisco Small Business 200 Series Smart Switch Administration Guide
132
10
Workflow4:
To rerun a Smartport macro after it has failed, perform the
following steps:
STEP 1
In the
Interface Settings
page, select an interface with Smartport type Unknown.
STEP 2
Click
Show Diagnostics
to see the problem.
STEP 3
Troubleshoot, then correct the problem. See the troubleshooting tip below.
STEP 4
Click Edit. A new window opens in which you can click Reset to reset the interface.
STEP 5
Return to the main page and reapply the macro using either Reapply (for devices
that are not switches, routers or APs) or Reapply Smartport Macro (for switches,
routers or APs) to run the Smartport Macro on the interface.
A second method of resetting single or multiple unknown interfaces is:
STEP 1
In the
Interface Settings
page, select the
Port Type
equals to
checkbox.
STEP 2
Select
Unknown
and click Go.
STEP 3
Click Reset All Unknown Smartports. Then reapply the macro as described above.
TIP
The reason that the macro failed might be a conflict with a configuration on the
interface made prior to applying the macro (most often encountered with security
and storm-control settings), a wrong port type, a typo or an incorrect command
within the user-defined macro, or an invalid parameter setting. Parameters are
checked for neither type nor boundary prior to the attempt to apply the macro,
therefore, an incorrect or invalid input to a parameter value will almost assuredly
cause failure when applying the macro.
Configuring Smartport Using The Web-based Interface
The Smartport feature is configured in the
Smartport >
Properties
,
Smartport
Type Settings
and
Interface Settings
pages.
For Voice VLAN configuration, see
Voice VLAN
.
For LLDP/CDP configuration, see the
Configuring LLDP
and
Configuring CDP
sections, respectively.