14
Attention!
Before starting the gate/gate must be moved to the completely closed position. Press the "
SEL
" button to move the gate to this position.
• Make sure that display "
D1
" is off and the LEDs "
L4
", "
L5
","
L6
", "
L7
" and "
L8
" are all lit .
• Open the "
Standard wiring diagram
" which is folded inside the last page of this manual and carry out the programming procedure.
PROGRAMMING PROCEDURE
(
Setting the programmer and the work times
)
Dynamic button
open-close
PRESS
PROG
Dynamic button
open-block
close-block
Automatic
reclosing
enabled
Automatic
reclosing
excluded
PRESS SEL
PRESS
PROG
PRESS SEL
ACTIVE
FUNCTION
Preflashing
enabled
PRESS
PROG
Preflashing
excluded
Warning light
output
fixed
Deceleration
anabled
PRESS
PROG
Deceleration
excluded
D1
PRESS THE PROG BUTTON FOR MORE
THAN 4 SECONDS: THE PARAMETER
DEFINITION LETTER "d" WILL APPEAR
ON THE DISPLAY (STAGE "A")
1...4... sec.
1... sec.
ACTIVE
FUNCTION
PRESS
SEL
1...20... sec.
AFTER 1 SECOND THE DIGIT "1" WILL APPEAR
(FIRST PROGRAMMING STEP). THIS NUMBER CAN BE
EITHER FLASHING OR FIXED
Note 1
Note 2
PRESS SEL
PRESS
PROG
Travel limits
enabled
WAIT FOR ABOUT 20 SECONDS WITHOUT PRESSING
ANY BUTTONS: THE PROGRAMMER WILL SAVE THE
PARAMETERS SET UP TO NOW AND WILL QUIT
PROGRAMMING.
PRESS
SEL
ALTERNATING
ALTERNATING
PRESS
SEL
PRESS
PROG
ALTERNATING
ALTERNATING
PRESS
PROG
FIXED
VALUE
PRESS
SEL
ALTERNATING
ALTERNATING
PRESS
PROG
FIXED
VALUE
FIXED
VALUE
PRESSING THE "PROG" BUTTON WILL MOVE YOU TO
STAGE "B"
. PROGRAMMING THE DECELERATION TIME.
THE VALUES CAN BE CHOSEN FROM 1 TO 4 SECONDS.
PRESS
PROG
PRESS SEL
1...20... sec.
WAIT FOR ABOUT 20 SECONDS WITHOUT PRESSING
ANY BUTTONS: THE PROGRAMMER WILL SAVE THE
PARAMETERS SET UP TO NOW AND WILL QUIT
PROGRAMMING.
PRESS
SEL
PRESS
PROG
Warning light
output
intermittent
SELECTION
1 SECOND
SELECTION
2 SECONDS
SELECTION
4 SECONDS
PRESS SEL
PRESS
PROG
Travel limits
excluded
PRESS SEL
Note 3
Note 4
Importing notes regarding the programmer settings
Note 1
Travel direction inversion only during the closing stage.
Note 2
The travel limits must always be enabled (number fixed)
Note 3
Deceleration must be excluded for fold up doors
Note 4
The
,
,
selection must be carried out even if deceleration is
excluded: It must be decided whether the electrical sensor works as
a travel limit in the last 1,2 or 4 seconds of movement in the closing
direction. You are advised to set a 2 second minimum
; if decel-
eration has been excluded you may also select
(especially if the
structure of the garage door could reduce the closing time after wear
and tear through time).
CONTINUE ON PAGE 15