CPEC300/306/310 Closed-Path Eddy-Covariance Systems
59
TABLE 6-8. Data Fields in the Diagnostic Output Table
Data Field Name
Description
Data Field
Included
irga_startup_f
Startup diagnostic flag
Always
irga_motor_spd_f
Motor speed diagnostic flag
Always
irga_tec_tmpr_f
Thermoelectric cooler (TEC) temperature
diagnostic flag
Always
irga_src_pwr_f
Source power diagnostic flag
Always
irga_src_tmpr_f
Source temperature diagnostic flag
Always
irga_src_curr_f
Source current diagnostic flag
Always
irga_off_f
Gas head power down diagnostic flag
Always
irga_sync_f
Synchronization diagnostic flag
Always
irga_amb_tmpr_f
Ambient temperature probe diagnostic flag
Always
irga_amb_press_f
Ambient pressure diagnostic flag
Always
irga_CO2_I_f
CO
2
I signal diagnostic flag
Always
irga_CO2_Io_f
CO
2
Io signal diagnostic flag
Always
irga_H2O_I_f
H
2
O I signal diagnostic flag
Always
irga_H2O_Io_f
H
2
O Io signal diagnostic flag
Always
irga_CO2_Io_var_f
CO
2
Io variation diagnostic flag
Always
irga_H2O_Io_var_f
H
2
O Io variation diagnostic flag
Always
irga_CO2_sig_strgth_f
CO
2
signal strength diagnostic flag
Always
irga_H2O_sig_strgth_f
H
2
O signal strength diagnostic flag
Always
irga_cal_err_f
Calibration file read error flag
Always
irga_htr_ctrl_off_f
Heater control off diagnostic flag
Always
irga_diff_press_f
Differential pressure out of bounds flag
Always
CO2_sig_strgth
CO
2
signal strength (service sample cell when
<80%, see EC155 user manual)
Always
H2O_sig_strgth
H
2
O signal strength (service sample cell when
<80%, see EC155 user manual)
Always
TABLE 6-9. Data Field in the EC100_Config_Notes Output Table
Data Field Name
Units
Description
Data Field Included
Config_type
String
A string indicating why the EC100 was
reconfigured
Always
mode
String
A string indicating the sampling mode. See
If system is a
CPEC310
site
String
A string indicating the sampling site. See
If system is a
CPEC310
bandwidth_freq
Hz
EC100 bandwidth (5, 10, 12, or 20 for 5
Hz, 10 Hz, 12.5 Hz, or 20 Hz respectively)
Always
Содержание CPEC300
Страница 1: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 10 18 Copyright 2018 Campbell Scientific Inc ...
Страница 17: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 8 FIGURE 4 8 CPEC306 system ...
Страница 54: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 45 ...
Страница 55: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 46 ...