Appendix H. Output Variables
H-6
at seven records per sequence, and sequences run every hour). The CPU has
storage allocated for 500 records (3 days).
The
zero_span
table is defined only if
VALVE_MODULE
=
True
. As a
result, only the last five values, associated with the scrub module, are optional
depending on the
SCRUB_MODULE
compile switch.
The value of the compile switches as shown in TABLE
constants as described in Section
(p. 36)
.
The code shown in
the table can be either V, S, or a combination of two of the codes.
•
V is defined if
VALVE_MODULE
=
True
•
S is defined if
SCRUB_MODULE
=
True
and
VALVE_MODULE
=
True
TABLE H-3. Values stored in table zero_ span
Compile
Switch
Variable Name
Units
Description
V
TIMESTAMP
TS
Date and time the record was measured
V
RECORD
RN
Record number
V
Sequence_Step
Status of the zero/span sequence
V
ValveNumber
Valve number (0 to 6); determines which zero/span valve is
selected
V
CO2_Avg
µmol∙mol
-1
Average of CO
2
V
H2O_Avg
mmol∙mol
-1
Average of H
2
O
V
diag_irga_Avg
Average of diag_irga
V
cell_tmpr_Avg
ºC
Average cell temperature
V
cell_press_Avg
kPa
Average cell pressure
V
CO2_signal_Avg
Average CO
2
signal
V
H2O_signal_Avg
Average H
2
O signal
V
diff_press_Avg
kPa
Average differential pressure
V
source_tmpr_Avg
ºC
Average source temperature
V
pump_ON_Avg
Fraction of time the pump was on
V
pump_flow_Avg
LPM
Average pump flow
V
pump_control_Avg
Average pump control value
V
pump_press_Avg
kPa
Average pump pressure
V
diag_CPEC_Avg
Average of diag_cpec
V
fast_samples
Number of samples included in the averages for values
measured in the main scan
V
buff_depth_Max
Maximum buffer depth during the output interval
V
process_time_Avg
µsec
Average processing time
V
PressOffset
kPa
Sample cell pressure measured with no flow; used to infer
valve flow
V
valve_flow_Avg
LPM
Average zero/span flow
V
valveControl_Avg
Average of zero/span flow control valve; can be from 0
(closed) to 1 (open)
V
PumpTmprOK_Avg
Fraction of time the pump temperature was within its
operating range
V
pump_tmpr_Avg
ºC
Average pump temperature
V
pump_heat_Avg
Fraction of time the pump heater was on
V
pump_fan_Avg
Fraction of time the pump fan was on
V
panel_tmpr_Avg
ºC
Average datalogger wiring panel temperature
Содержание CPEC300
Страница 1: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 10 18 Copyright 2018 Campbell Scientific Inc ...
Страница 17: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 8 FIGURE 4 8 CPEC306 system ...
Страница 54: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 45 ...
Страница 55: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 46 ...