CPEC300/306/310 Closed-Path Eddy-Covariance Systems
66
TABLE 6-11. Data Fields in the Flux_CSFormat Data Output Table
Data Field Name
Units
Description
Data Field Included
T_SONIC_SIGMA
deg C
Standard deviation of sonic
temperature
Always
sonic_azimuth
decimal
degrees
Compass direction in which the sonic
negative x-axis points
Always
WS
m·s
-1
Average wind speed
Always
WS_RSLT
m·s
-1
Average horizontal wind speed
Always
WD_SONIC
decimal
degrees
Average wind direction in the sonic
coordinate system
Always
WD_SIGMA
decimal
degrees
Standard deviation of wind direction
Always
WD
decimal
degrees
Average compass wind direction
Always
WS_MAX
m·s
-1
Maximum wind speed
Always
CO2
µmol·mol
-1
Average CO
2
dry molar mixing ratio
Always
CO2_SIGMA
µmol·mol
-1
Standard deviation of CO
2
dry molar
mixing ratio
Always
CO2_density
mg·m
-3
Average CO
2
mass density
Always
CO2_density_SIGMA
mg·m
-3
Standard deviation of CO
2
mass
density
Always
H2O
mmol·mol-1
Average H
2
O dry molar mixing ratio
Always
H2O_SIGMA
mmol·mol-1
Standard deviation of H
2
O dry molar
mixing ratio
Always
H2O_density
mmol·mol
-1
Water vapor mass density
Always
H2O_density_SIGMA
mmol·mol
-1
Standard deviation of water vapor
mass density
Always
CO2_sig_strgth_Min
–
Minimum CO
2
signal strength
Always
H2O_sig_strgth_Min
–
Minimum H
2
O signal strength
Always
FW
deg C
Average fine-wire thermocouple
temperature
If FW05, FW1, or FW3
is used
FW_SIGMA
deg C
Standard deviation of fine-wire
thermocouple temperature
If FW05, FW1, or FW3
is used
P
mm
Total precipitation
If TE525MM is used
NETRAD_meas
W·m
-2
Average net radiation (raw, not
corrected for wind)
If NR-LITE2 is used
ALB
–
Average albedo
If CNR4 or NR01
is used
SW_IN
W·m
-2
Average incoming short wave
radiation
If LI200, CS300,
CNR4, or NR01
is used
SW_OUT
W·m
-2
Average outgoing short wave
radiation
If CNR4 or NR01
is used
Содержание CPEC300
Страница 1: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 10 18 Copyright 2018 Campbell Scientific Inc ...
Страница 17: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 8 FIGURE 4 8 CPEC306 system ...
Страница 54: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 45 ...
Страница 55: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 46 ...