CPEC300/306/310 Closed-Path Eddy-Covariance Systems
33
FIGURE 5-10. Wiring to EC100 electronics
5.3.3 Pump Module Cable for a CPEC300
Ensure the CPEC300 system is not powered, and connect the pump module
cable to the bottom of the CPEC306 or CPEC310 system enclosure (or
CPEC300 pump module enclosure).
5.3.4 Apply Power
All CPEC300-series systems require a 10.5 to 16.0 Vdc power source. Its
average power consumption is 12 W typically but will be slightly higher at
cold temperatures, especially at startup in cold weather. In typical remote
applications the power will be supplied from a user-provided 12 Vdc battery
system charged with solar panels.
Before applying power, verify all of the tubes and cables have
been connected according to the instructions above.
To reduce the risk of shorting the power supply, especially
when using batteries, connect the power cable to the
CPEC300-series system first, then connect to the power
source. Carefully design any DC power source to ensure
uninterrupted power. If needed, contact Campbell Scientific
for assistance.
Connect a power cable (CABLEPCBL-L) from the CPEC306 and CPEC310
power terminals, as shown in FIGURE
, to a user-supplied, 12 Vdc power
supply.
For the CPEC300, the power cables will be plugged into the orange splicing
switches attached to the top of the enclosure, as shown in FIGURE
NOTE
CAUTION
EC100 Power
Cable
EC100 SDM
Cable
Содержание CPEC300
Страница 1: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 10 18 Copyright 2018 Campbell Scientific Inc ...
Страница 17: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 8 FIGURE 4 8 CPEC306 system ...
Страница 54: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 45 ...
Страница 55: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 46 ...