CPEC300/306/310 Closed-Path Eddy-Covariance Systems
76
TABLE 6-12. Data fields in the Flux_Notes Output Table
Data Field Name
Units
Description
Data Field
Included
MAX_LAG
scans
Maximum number of scans to lag gas
analyzer or fine-wire thermocouple data
with respect to sonic data when doing
cross correlation for covariance
maximization. For example, if
MAX_LAG = 2, the program will
consider lags of
−
2,
−
1, 0, +1, and +2.
Always
lag_CO2
scans
The lag applied to CO
2
data with
respect to sonic data that maximizes
covariance
Always
lag_H2O
Scans
The lag applied to H
2
O data with
respect to sonic data that maximizes
covariance
Always
lag_FW
scans
The lag applied to fine-wire
thermocouple data with respect to sonic
data that maximizes covariance
Always
FreqFactor_UW_VW
number
Frequency correction factor applied to
momentum fluxes
Always
FreqFactor_WT_SONIC
number
Frequency correction factor applied to
wTs covariance
Always
FreqFactor_WCO2
number
Frequency correction factor applied to
wCO
2
covariance
Always
FreqFactor_WH2O
Number
Frequency correction factor applied to
wH
2
O covariance
Always
FreqFactor_WFW
number
Frequency correction factor applied to
fine-wire thermocouple derived wFW
covariance
Always
rho_d
g·m
-3
Average density of dry air calculated
from EC sensors
Always
rho_a
kg·m
-3
Average density of ambient moist air
calculated from EC sensors
Always
rho_d_probe
g·m
-3
Average density of dry air calculated
from temp/RH probe measurements
If a temp/RH
probe is used
rho_a_probe
kg·m
-3
Average density of ambient moist air
calculated from temp/RH probe
measurements
If a temp/RH
probe is used
Cp
J·kg
-1·
K
-1
Specific heat of ambient (moist) air at
constant pressure
Always
Lv
J·g
-1
Latent heat of vaporization
Always
T_panel
deg C
Average temperature of the datalogger
wiring panel
Always
Содержание CPEC300
Страница 1: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 10 18 Copyright 2018 Campbell Scientific Inc ...
Страница 17: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 8 FIGURE 4 8 CPEC306 system ...
Страница 54: ...CPEC300 306 310 Closed Path Eddy Covariance Systems 45 ...