PTP 800 Series User Guide
I nst alling ant ennas and ODUs
phn- 2513_004v000 ( Oct 2012)
5- 29
7
Remove the protective film from the coupler remote mount port.
8
Apply silicone grease to the ‘O’ ring of the remote mount transition.
9
Fit the coupler to the remote mount bracket by following this sequence:
Initially, hand tighten two of the diagonally opposed M8 bolts with the Allen Key
supplied in the kit.
Using the latch clamp, clip the same two corners.
Repeat the above on the remaining two diagonally opposed bolts and clips.
Torque down all four M8 bolts to 18Nm.