Coupler losses and isolation
contains ODU port return losses and isolation figures for Cambium-supplied ODU
couplers. These figures apply to both symmetric and asymmetric couplers.
Ta ble 9 2
ODU coupler ret urn losses and isolat ion
Ba n ds
OD U p or t r e t u r n loss
I sola t ion be t w e e n OD U p or t s
6 GHz
18 dB minimum
20 dB minimum
7 GHz to 38 GHz
20 dB maximum
20 dB minimum
contains ODU port insertion losses for Cambium-supplied ODU couplers.
Ta ble 9 3
ODU coupler insert ion losses
Ba n ds
Cou p le r t yp e
OD U p or t m a x im u m in se r t ion losse s
6 GHz
3 dB symmetric
6 dB asymmetric
Main 1.9 dB, Standby 6.5 dB
7 GHz to 26 GHz
3 dB symmetric
3.8 dB
6 dB asymmetric
Main 1.8 dB, Standby 7.2 dB
32 GHz to 38 GHz
3 dB symmetric
4.0 dB
6 dB asymmetric
Main 2.0 dB, Standby 7.4 dB
Содержание PTP 800 Series
Страница 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Страница 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Страница 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Страница 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Страница 418: ...Replacing IRFU components Chapter 5 Installation 5 96 phn 2513_004v000 Oct 2012 Figure 1 1 0 IRFU components example ...
Страница 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Страница 552: ...Configuring for FIPS 140 2 applications Chapter 6 Configuration and alignment 6 124 phn 2513_004v000 Oct 2012 ...
Страница 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...
Страница 648: ...Glossary I V phn 2513_004v000 Oct 2012 ...