PTP 800 Series User Guide
Managing alarm s and event s
phn- 2513_004v000 ( Oct 2012)
7- 19
Management Port Ethernet Speed Status
Definition
: In a 1+1 Hot Standby configuration, this indicates if the Ethernet Speed of the
Management port is below that of its neighbor. For example, where the Management port
has negotiated at 10BASE-T but the neighbor has negotiated at 100BASE-T.
Cause and action:
This could be due to a difference between the configuration of the
Management ports of the neighbor CMUs (see LAN configuration page) or in the
configuration of the two ports at the network equipment. A fault in the Ethernet cable
could also cause an Ethernet port to negotiate at a lower speed.
Management port status
Definition
: The status of the management port if out-of-band management is being used.
Cause and action:
for values and their meanings.
Protection Availability Status
Definition
: This indicates if an end of a 1+1 Hot Standby link is not protected, for
example due to the inactive unit exhibiting a fault, the protection cable being
disconnected, the configuration of the inactive unit being incompatible with that of the
active unit, or Fault Protection Switching being set to disabled. If the end is not protected,
the active unit will indicate 'Not Protected' and the inactive unit will indicate ‘Not
Protecting’.
Cause and action:
If a unit is indicating that it is not protected or not protecting, check
the following:
•
Check that the configuration of the two neighbors is compatible. See <attribute
name> neighbor compatibility.
•
Check that the transmitter of the inactive unit is not muted. This is controlled on the
Configuration page or the Protection Page.
•
Check that the two neighbors are not in Alignment Mode (See Alignment Mode (top of
this table)).
•
Check that Fault Protection Switching is Enabled. This can be set from the Protection
Configuration page or the Protected Link Management page.
•
Check that the Protection Interface is operating correctly (see Protection Interface
Status)
•
Check that the inactive unit is not exhibiting any faults.
Содержание PTP 800 Series
Страница 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Страница 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Страница 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Страница 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Страница 418: ...Replacing IRFU components Chapter 5 Installation 5 96 phn 2513_004v000 Oct 2012 Figure 1 1 0 IRFU components example ...
Страница 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Страница 552: ...Configuring for FIPS 140 2 applications Chapter 6 Configuration and alignment 6 124 phn 2513_004v000 Oct 2012 ...
Страница 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...
Страница 648: ...Glossary I V phn 2513_004v000 Oct 2012 ...