Managing alarm s and event s
Chapt er 7: Operat ion
7- 16
phn- 2513_004v000 ( Oct 2012)
The alarms are defined as follows:
<attribute name> Neighbor Compatibility
Definition
: In order for a 1+1 Hot Standby link end to be correctly protected, a number of
key attributes must be configured to be compatible in the two neighbor CMUs. If a key
attribute is configured to be mismatched, an associated alarm will be displayed on the
Home page of both neighbor CMUs. Each alarm has the form <attribute name> neighbor
compatibility, for example ‘Radio License Tx Freq Neighbor Compatibility’ indicates that
the Radio License Tx Freq is different for the neighbor CMUs.
Cause and action:
Correct the attribute which is indicating the mismatch.
Alignment mode
Definition
: The CMU is in alignment mode.
Cause and action:
This should only occur during installation or maintenance when the
wireless link is being aligned. To take a unit out of alignment mode, access the Installation
Wizard (see
Task 7: Configuring wireless interface
Data port configuration mismatch
Definition
: The Ethernet configuration of the data port is not compatible with the
connected network equipment.
Cause and action:
This is probably due to a configuration error such as an auto-
negotiation or forced configuration mismatch.
Data port disabled warning
Definition
: The fiber and copper data port has been disabled by means of the SNMP MIB.
Cause and action:
The port has been disabled by a network management system. The
web browser provides no means of disabling this port.
Data Port Ethernet Speed Status
Definition
: In a 1+1 Hot Standby configuration, this indicates if the Ethernet Speed of the
Data port is below that of its neighbor. For example, where the Data Port has negotiated at
100BASE-T but the neighbor has negotiated at 1000BASE-T.
Cause and action:
This could be due to a difference between the configuration of the
Data ports of the neighbor CMUs (see LAN Configuration page) or in the configuration of
the two ports at the network equipment. A fault in the Ethernet cable could also cause an
Ethernet port to negotiate at a lower speed.
Содержание PTP 800 Series
Страница 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Страница 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Страница 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Страница 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Страница 418: ...Replacing IRFU components Chapter 5 Installation 5 96 phn 2513_004v000 Oct 2012 Figure 1 1 0 IRFU components example ...
Страница 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Страница 552: ...Configuring for FIPS 140 2 applications Chapter 6 Configuration and alignment 6 124 phn 2513_004v000 Oct 2012 ...
Страница 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...
Страница 648: ...Glossary I V phn 2513_004v000 Oct 2012 ...