PTP 800 Series User Guide
FI PS 140- 2
phn- 2513_004v000 ( Oct 2012)
1- 71
Indication of FIPS 140-2 capability
The FIPS 140-2 capability is indicated by a distinctive symbol displayed at the top of the
navigation bar in the web-based interface, as shown in
Figu r e 3 7
I ndicat ion of FI PS 140- 2 capabilit y
FIPS 140-2 mode
PTP 800 operates in the FIPS 140-2 mode when all of the following are true:
•
The PTP 800 is FIPS 140-2 capable.
•
The HTTPS/TLS management interface is enabled.
•
The HTTP management interface is disabled.
•
The Telnet management interface is disabled.
•
SNMP control of HTTP and Telnet is disabled.
•
AES encryption is enabled at the wireless interface.
•
The HTTPS/TLS management interface is configured for identity-based user accounts.
•
RADIUS authentication of web-based users is disabled.
FIPS operational mode alarm
The FIPS operational mode alarm indicates that the unit is FIPS 140-2 capable, but has not
been configured correctly for FIPS 140-2 operation. The FIPS operational mode alarm
appears as shown in
Figu r e 3 8
FI PS operat ional m ode alarm
Содержание PTP 800 Series
Страница 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Страница 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Страница 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Страница 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Страница 418: ...Replacing IRFU components Chapter 5 Installation 5 96 phn 2513_004v000 Oct 2012 Figure 1 1 0 IRFU components example ...
Страница 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Страница 552: ...Configuring for FIPS 140 2 applications Chapter 6 Configuration and alignment 6 124 phn 2513_004v000 Oct 2012 ...
Страница 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...
Страница 648: ...Glossary I V phn 2513_004v000 Oct 2012 ...