Test ing t he ODU and I F cable
Chapt er 5: I nst allat ion
5- 62
phn- 2513_004v000 ( Oct 2012)
To prepare for pre-power testing, proceed as follows:
1
Connect the analyzer to the first LPU (
2
Connect the first LPU to the second (
3
Check that the second LPU is disconnected from the cable that leads to the ODU
(
) (the second LPU and ODU are reconnected during testing).
4
Power on the analyzer.
When these preparations are complete, perform the following tests:
•
on page
•
Testing cable loss
The purpose of this test is to ensure that the total cable loss is within acceptable limits.
Before performing this test, ensure that the test equipment is set up as described in
To measure cable loss, proceed as follows:
1
Select the ‘cable loss-one port’ mode of the cable analyzer (
.
2
Set the frequency of measurement to:
F1 = 350MHz
F2 = 400MHz.
3
Calibrate the instrument for the selected frequencies, using the correct
calibration kit.
4
Before connecting the ODU, obtain a plot of cable loss and check that it is within
the expected limits for the given cable length (
). Compare it to
examples of good installations (
5
Connect the ODU.
6
Observe the effect of the ODU connection on the plot of cable loss.
Compare it to examples of good installations (
If there is little or no change to the plot when the ODU is connected, it indicates
a short or open circuit on the cable.
7
Keep a copy of the cable loss plots so that they can be compared with
subsequent plots to determine if there is any degradation with time.
Содержание PTP 800 Series
Страница 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Страница 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Страница 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Страница 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Страница 418: ...Replacing IRFU components Chapter 5 Installation 5 96 phn 2513_004v000 Oct 2012 Figure 1 1 0 IRFU components example ...
Страница 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Страница 552: ...Configuring for FIPS 140 2 applications Chapter 6 Configuration and alignment 6 124 phn 2513_004v000 Oct 2012 ...
Страница 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...
Страница 648: ...Glossary I V phn 2513_004v000 Oct 2012 ...