background image

INSTRUCTION MANUAL

HUB-SDM5

7/04

C o p y r i g h t   ( c )   2 0 0 4

C a m p b e l l   S c i e n t i f i c ,   I n c .

Содержание HUB-SDM5

Страница 1: ...INSTRUCTION MANUAL HUB SDM5 7 04 C o p y r i g h t c 2 0 0 4 C a m p b e l l S c i e n t i f i c I n c ...

Страница 2: ...ranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization The following contact information is for US and International customers residing in countries served by Campbell Scientific Inc directly Affili...

Страница 3: ...rinted version of this document Use the Adobe Acrobat bookmarks tab for links to specific sections 1 Introduction 1 2 HUB SDM5 Specifications 1 3 General 1 4 Installation and Wiring 1 4 1 Wiring SDM Devices 2 4 2 Wiring SDI 12 Devices 3 5 Generic Junction Box 4 6 Maintenance 4 i ...

Страница 4: ...This is a blank page ...

Страница 5: ...ngth 17 8 cm 7 0 Width 19 7 cm 7 75 Depth 13 3 cm 5 25 Weight 0 82 kg 1 8 lbs 3 General Inside the HUB SDM5 enclosure are five pairs of terminal strips These terminal strips are mounted on a DIN rail and an orange end cap separates each pair Each pair of terminal strips is connected to each other by means of a jumper The terminal strips are used to connect up to six wires to each other The wires a...

Страница 6: ...een completely inserted and has bottomed out firmly press the screwdriver down until the guillotine snaps open Insert and hold the wire as the screwdriver is removed 4 1 Wiring SDM Devices Before connecting the SDM signal cable to the terminals strip the wire insulation back to expose inch of bare wire Feed the cable through the bulkhead fitting Neatly separate the five wires into the following or...

Страница 7: ...ch of bare wire Feed the cable through the bulkhead fitting Neatly separate the four wires into the following order SDI 12 data SDI 12 power SDI 12 ground SDI 12 shield FIGURE 3 HUB SDM5 connecting three SDI 12 devices to a datalogger To SDI 12 sensor 1 To SDI 12 sensor 2 To SDI 12 sensor 3 SDM Devices Datalogger or second HUB SDM5 SDM Data SDM Clock SDM Enable SDM Ground SDM Shield Sealed Bulkhea...

Страница 8: ... to each other Three ten conductor cables can be connected to each other by removing the jumper between the terminal strips Use a small screwdriver to pry the jumper out 6 Maintenance There are no user serviceable parts in the HUB SDM5 Make sure that all unused bulkhead fittings are sealed with a plug and that the lid is tightly fastened SDI 12 Devices Datalogger or second HUB SDM5 SDI 12 Data SDI...

Страница 9: ...This is a blank page ...

Страница 10: ... campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Ltd CSL Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UNITED KINGDOM www campbellsci co uk sales campbellsci co uk Campbell Scientific Ltd France Miniparc du Verger Bat H 1 rue de Te...

Отзывы: