background image

SM24-1000SFP-AH

Gigabit Ethernet Switch

Installation Guide

Содержание SM24-1000SFP-AH

Страница 1: ...SM24 1000SFP AH Gigabit Ethernet Switch Installation Guide ...

Страница 2: ......

Страница 3: ...ide SM24 1000SFP AH Gigabit Ethernet Switch Layer 2 FTTH Switch with 24 Gigabit Ethernet SFP Slots 2 10 Gigabit Ethernet XFP Slots 2 10 Gigabit Ethernet Extender Module Slots XFP 1 Fast Ethernet Management Port RJ 45 ...

Страница 4: ...SM24 1000SFP AH E112009 DT R01 ...

Страница 5: ...nterference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment You may use unshielded tw...

Страница 6: ...atic Discharge according to EN 61000 4 2 1995 Contact Discharge 4 kV Air Discharge 8 kV Radio frequency electromagnetic field according to EN 61000 4 3 1996 80 1000 MHz with 1 kHz AM 80 Modulation 3 V m Electrical fast transient burst according to EN 61000 4 4 1995 AC DC power supply 1 kV Data Signal lines 0 5 kV Surge immunity test according to EN 61000 4 5 1995 AC DC Line to Line 1 kV AC DC Line...

Страница 7: ...d circuit breaker on the branch circuit When using a DC power conversion module a listed circuit breaker or other appropriate disconnect device must be provided as part of the building installation France and Peru only This unit cannot be powered from IT supplies If your supplies are of IT type this unit must be powered by 230 V 2P T via an isolation transformer ratio 1 1 with the secondary connec...

Страница 8: ...sion extrêmement basse de sécurité qui est conforme à la norme IEC 60950 Ces conditions ne sont maintenues que si l équipement auquel il est raccordé fonctionne dans les mêmes conditions France et Pérou uniquement Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre Si vos alimentations sont du type impédance à la terre ce groupe doit être alimenté par une tension de 230 V ...

Страница 9: ...0950 Diese Bedingungen sind nur gegeben wenn auch die an das Gerät angeschlossenen Geräte unter SELV Bedingungen betrieben werden Cordon électrique Il doit être agréé dans le pays d utilisation Etats Unis et Canada Le cordon doit avoir reçu l homologation des UL et un certificat de la CSA Les spécifications minimales pour un cable flexible sont AWG No 18 ou AWG No 16 pour un cable de longueur infé...

Страница 10: ...3VVF3GO 75 Mindestanforderung sein und die Aufschrift HAR oder BASEC tragen Der Netzstecker muß die Norm CEE 7 7 erfüllen SCHUKO Warning This product does not contain any serviceable user parts Warning Installation and removal of the unit must be carried out by qualified personnel only Warning When connecting this device to a power outlet connect the field ground lead on the tri pole power plug to...

Страница 11: ...ed in the printing process are non toxic Purpose This guide details the hardware features of the switches including their physical and performance related characteristics and how to install each switch Audience This guide is for system administrators with a working knowledge of network management You should be familiar with switching and networking concepts Related Publications The following publi...

Страница 12: ...viii ...

Страница 13: ... 1 6 Expandability 1 6 Performance 1 7 Management 1 7 Chapter 2 Network Planning 2 1 Fiber To The Home FTTH 2 1 Connection Examples 2 2 Downlink Fiber Connections 2 2 Uplink Connections 2 3 Management Connections 2 4 Private VLAN Connections 2 5 Application Notes 2 6 Chapter 3 Installing the Switch 3 1 Selecting a Site 3 1 Ethernet Cabling 3 1 Equipment Checklist 3 2 Package Contents 3 2 Optional ...

Страница 14: ...ctivity Rules 4 5 1000BASE T Cable Requirements 4 5 10 Gbps Ethernet Collision Domain 4 6 1000 Mbps Gigabit Ethernet Cable Lengths 4 6 100 Mbps Fast Ethernet Cable Lengths 4 7 10 Mbps Ethernet Cable Lengths 4 7 Cable Labeling and Connection Records 4 7 Appendix A Troubleshooting A 1 Diagnosing Switch Indicators A 1 Power and Cooling Problems A 2 Installation A 2 In Band Access A 2 Appendix B Cable...

Страница 15: ...ents Appendix C Specifications C 1 Physical Characteristics C 1 Switch Features C 2 Management Features C 2 Standards C 3 Compliances C 3 Extender Modules C 4 10 Gigabit Extender Module XFP C 4 Glossary Index ...

Страница 16: ...it Ethernet Cable Length 4 6 Table 4 5 Maximum 1000BASE SX Gigabit Ethernet Cable Length 4 6 Table 4 6 Maximum 1000BASE LX Gigabit Ethernet Cable Length 4 6 Table 4 7 Maximum 1000BASE LH Gigabit Ethernet Cable Length 4 7 Table 4 8 Maximum 1000BASE BX10 U Gigabit Ethernet Cable Length 4 7 Table 4 9 Maximum Fast Ethernet Cable Length 4 7 Table 4 10 Maximum Ethernet Cable Length 4 7 Table A 1 Trouble...

Страница 17: ...ing the Switch in a Rack 3 4 Figure 3 4 Attaching the Adhesive Feet 3 4 Figure 3 5 Installing an Optional Module 3 5 Figure 3 6 Inserting an SFP XFP Transceiver into a Slot 3 6 Figure 3 7 DC Plug Connections 3 8 Figure 3 8 AC Power Receptacle 3 9 Figure 3 9 Serial Port RJ 45 Pin Out 3 10 Figure 3 10 Alarm Port D 15 Pin Out 3 11 Figure 3 11 External Alarm I O Connections 3 12 Figure 4 1 Making Twis...

Страница 18: ...xiv Figures ...

Страница 19: ... the switch either in the CO or anywhere along the path between the CO and the subscriber The switch has one 10 100BASE TX port for dedicated management access which can be operated outside the data channel It has an SNMP based management agent embedded on the main board which supports both in band and out of band access using a Web browser SNMP RMON or Telnet This switch can enhance your network ...

Страница 20: ...t the on board web agent or SNMP based network management software The Craft port RJ 45 provides a dedicated management channel that operates outside of the data transport network This makes it possible to re configure or troubleshoot the switch over either a local or remote connection to the Craft port when access via the data channel is not possible or deemed insecure For a detailed description ...

Страница 21: ...anagement Port The 10 100BASE TX port labeled Craft provides a dedicated management interface which is segregated from the data traffic crossing the other ports This port supports auto negotiation so the optimum transmission mode half or full duplex and data rate 10 or 100 Mbps can be selected automatically if this feature is also supported by the attached device However note that the interface co...

Страница 22: ...asy viewing are shown below and described in the following tables Figure 1 3 Port and System LEDs Table 1 1 Port and System Status LEDs LED Condition Status Major Red Indicates presence within the system of one or more major traffic affecting system alarm s that are not masked by the alarm filter Minor Amber Indicates presence within the system of one or more minor traffic affecting system alarm s...

Страница 23: ...de Off Not operating in stack mode Link Activity Ports 1 27 Craft Port Green Port has a valid link Flashing Green Flashing indicates activity on the port Off The link is down Power Module 48V 12V 24V 12V or AC 12V Green DC or AC power is functioning normally Off External power not connected or has failed Stacking will be supported in future releases The 48V 24V AC LEDs on the left indicate the sta...

Страница 24: ...ernet XFP slots provide 40 Gbps of aggregate bandwidth for network uplink to the Central Office or for downlink to another aggregation device 10 100BASE TX management port supports auto MDI MDI X pinout selection IEEE 802 3 2005 Ethernet Fast Ethernet Gigabit Ethernet and IEEE 802 3ae 10 Gigabit Ethernet compliance ensures compatibility with standards based network cards and switches from any vend...

Страница 25: ...trol using back pressure for half duplex and IEEE 802 3x for full duplex Management At a glance LEDs for easy troubleshooting Network management agent Manages switch in band or out of band Hardware assisted remote monitoring RMON statistics collection Supports console Telnet SSH SNMP v1 v2c v3 RMON 4 groups and web based interface Dedicated management port for in band access User name and password...

Страница 26: ...Introduction 1 8 1 ...

Страница 27: ...ctions that run from the service provider s central office CO directly to the subscriber s CPE 1000BASE SX transceivers support downlink connections to the subscriber which can run up to 550 meters While 1000BASE LX LH transceivers support uplink connections to the CO or downlinks to intermediate aggregation nodes which can run up to 10 or 40 km respectively The switch also provides two 10 Gigabit...

Страница 28: ... to the switch over a dedicated management channel outside of the data network Some typical connection configurations are described below Downlink Fiber Connections Fiber optic technology allows for longer cabling than any other media type A 1000BASE LX single mode fiber link from the switch can connect to a subscriber up to 10 km away A CPE is installed inside a subscriber s premises so there are...

Страница 29: ... each port in the trunk the additional port provides redundancy by taking over the load if the other trunk port fails The figure below illustrates a trunk connection to other switches Figure 2 2 Uplink Fiber Connections First Level Fiber Aggregation Switch or Layer 3 Router Link to Internet POP 10GBASE ER fiber trunk connection to Layer 2 3 switch up to 40 km FTTH Switch Internet SM24 1000SFP AH G...

Страница 30: ... or troubleshoot the switch over either a local or remote connection to the management port when access via the data channel is not possible or deemed insecure The figure below illustrates management port connections to FTTH switches Figure 2 3 Management Port Connections Ethernet Switch Management Station 10 100BASE TX UTP connections to Ethernet switch up to 100 m FTTH Switches SM24 1000SFP AH G...

Страница 31: ...ecurity for each subscriber Furthermore the switch can control the bandwidth of downlink connections using traffic rate limiting Each Gigabit downlink port can be limited to values from 1 Mbps to 1 Gbps depending on the needs of the individual user The service provider can then charge subscribers according to the bandwidth provided The figure below illustrates Private VLAN connections to the switc...

Страница 32: ...tocol router 3 As a general rule the length of fiber optic cable for a single switched link should not exceed 1000BASE SX 550 m 1805 ft for multimode fiber duplex fiber 1000BASE LX 10 km 6 2 miles for single mode fiber duplex fiber 1000BASE LH 40 km 24 9 miles for single mode fiber duplex fiber 10GBASE SR 300 m 984 ft for single mode fiber duplex fiber 10GBASE LR 10 km 6 2 miles for single mode fi...

Страница 33: ...om power lines fluorescent lighting fixtures and other sources of electrical interference such as radios and transmitters Make sure that the unit is connected to a separate grounded power outlet within 2 m 6 6 feet of each device and is powered from an independent circuit breaker As with any equipment using a filter or surge suppressor is recommended This switch provides three power module options...

Страница 34: ...t Package Contents 26 port Gigabit Ethernet Switch SM24 1000SFP AH Four adhesive foot pads Bracket Mounting Kit containing two brackets and eight screws for attaching the brackets to the switch Power cord either US Continental Europe or UK Console cable RJ 45 to RS 232 This Installation Guide Management Guide CD Note Power supply not included Optional Rack Mounting Equipment If you plan to rack mo...

Страница 35: ...the ambient room temperature check that the rack environment temperature is within the specified operating temperature range See page C 2 Mechanical Loading Do not place any equipment on top of a rack mounted unit Circuit Overloading Be sure that the supply circuit to the rack assembly is not overloaded Grounding Rack mounted equipment should be properly grounded To rack mount devices 1 Attach the...

Страница 36: ...iple switches mount them in the rack one below the other in any order Desktop or Shelf Mounting 1 Attach the four adhesive feet to the bottom of the first switch Figure 3 4 Attaching the Adhesive Feet 2 Set the device on a flat surface near an external power source making sure there are at least two inches of space on all sides for proper air flow P25 P25 P26 P26 Craft Console 17 18 19 20 21 22 23...

Страница 37: ...alled module from the appropriate slot by removing the two screws with a flat head screwdriver 2 Before opening the package that contains the module touch the bag to the switch casing to discharge any potential static electricity Also it is recommended to use an ESD wrist strap during installation 3 Remove the module from the anti static shielded bag 4 Holding the module level guide it into the ca...

Страница 38: ... XFP transceiver do the following 1 Consider network and cabling requirements to select an appropriate transceiver type 2 Insert the transceiver with the optical connector facing outward and the slot connector facing down Note that SFP XFP transceivers are keyed so they can only be installed in the correct orientation 3 Slide the transceiver into the slot until it clicks into place Notes 1 SFP XFP...

Страница 39: ...AC and DC power conversion modules Connecting DC Power When a 48 VDC VDC power conversion module is installed in the switch an external DC power supply must be connected to the DC power connection on the left side of the front panel Warning Before wiring the DC plug or connecting power to the switch ensure that power to the feed lines is turned off at the supply circuit breaker or disconnected fro...

Страница 40: ... with the switch as shown below The power leads are labeled on the front of the chassis above the DC power connection block The 48 VDC power feed uses the 48VDC input and RETA B Return lines for power source A and B respectively Use a small flat tip screwdriver to loosen the screws on the power plug and open the wire clamps 6 Insert the wire leads into the openings shown in the figure below Each l...

Страница 41: ...have installed both a primary and redundant power conversion module verify that the LEDs on both modules are lit as indicated in the preceding step Connecting AC Power When a universal AC power module is installed in the switch external AC power must be supplied to the module To connect the switch to a power source 1 First verify that the external AC power supply can provide 100 to 240 VAC 50 60 H...

Страница 42: ...ront panel is used to connect to the switch for out of band console configuration The on board configuration program can be accessed from a terminal or a PC running a terminal emulation program The pin assignments used to connect to the serial port are provided in the following table Figure 3 9 Serial Port RJ 45 Pin Out Wiring Map for Serial Cable The serial port s configuration requirements are a...

Страница 43: ... P indicates positive input External alarm input 3 external relay dry contact closure to pin 13 4 ALARM_IN4_EXT_P External alarm input 4 external relay dry contact closure to pin 8 5 No Contact 6 MJR_ALARM_NO Normally open during major alarm state 7 MNR_ALARM_NO Normally open during minor alarm state 8 ALARM_IN4_EXT_RTN RTN indicates return to Ground External alarm input 4 external relay dry conta...

Страница 44: ... 4 NC NO COM Major Alarm NC NO COM Minor Alarm External Alarm Input 1 External Alarm Input 2 External Alarm Input 3 To backplane via internal signal converter circuits External input uses dry relay contact to pins 14 15 13 and 8 for grounding For active alarm the relay is closed Alarm Connector External Alarm Input 4 ALARM_IN1_EXT_P ALARM_IN1_EXT_RTN Alarm input is isolated by photo coupler ...

Страница 45: ...oth ends Use Category 5 5e or 6 cable for 1000BASE T connections Category 5 or better for 100BASE TX connections and Category 3 or better for 10BASE T connections Cabling Guidelines The RJ 45 ports on the switch support automatic MDI MDI X pinout configuration so you can use standard straight through twisted pair cables to connect to any other network device PCs servers switches routers or hubs Se...

Страница 46: ...transceivers on the switch s front panel can connect directly to a CPE at the subscriber s premises The transceiver ports require multimode duplex fiber optic cable with an LC connector at the switch end The connector used at the other end of the cable depends on the target device When connecting to a CPE the fiber cable is normally hard wired directly to the unit When connecting to another switch...

Страница 47: ...ll moistened with a little ethanol Dirty fiber terminators on fiber cables will impair the quality of the light transmitted through the cable and lead to degraded performance on the port 3 When running cable to a subscriber connect one end of the cable to the LC connector on one of the switch s SFP transceivers and the other end to the CPE at the subscriber s premises Most CPEs require the fiber c...

Страница 48: ...avelength for both transmit and receive signals SR 850 nm LR 1310 nm ER 1550 nm Warning These switches use lasers to transmit signals over fiber optic cable The lasers are compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation However you should never look directly at a transmit port when it is powered on Note When selecting a fiber device consid...

Страница 49: ...sion domains you should not include the switch or connected cabling in your calculations for cascade length involving other devices 1000BASE T Cable Requirements All Category 5 UTP cables that are used for 100BASE TX connections should also work for 1000BASE T providing that all four wire pairs are connected However it is recommended that for all critical connections or any new cable installations...

Страница 50: ...icron single mode fiber N A 10 km 6 2 miles LC Table 4 3 Maximum 10GBASE ER 10 Gigabit Ethernet Cable Length Fiber Size Fiber Bandwidth Maximum Cable Length Connector 9 125 micron single mode fiber N A 40 km 24 85 miles LC Table 4 4 Maximum 1000BASE T Gigabit Ethernet Cable Length Cable Type Maximum Cable Length Connector Category 5 5e 6 100 ohm UTP or STP 100 m 328 ft RJ 45 Table 4 5 Maximum 1000...

Страница 51: ...ngth of each cable and the maximum cable length supported by the switch ports For ease of understanding use a location based key when assigning prefixes to your cable labeling Table 4 7 Maximum 1000BASE LH Gigabit Ethernet Cable Length Fiber Size Fiber Bandwidth Maximum Cable Length Connector 9 125 micron single mode fiber N A 2 m 40 km 7 ft 24 9 miles LC Table 4 8 Maximum 1000BASE BX10 U Gigabit ...

Страница 52: ...ial numbers for cables that originate from the same equipment Differentiate between racks by naming accordingly Label each separate piece of equipment Display a copy of your equipment map including keys to all abbreviations at each equipment rack ...

Страница 53: ... problem Power cycle the switch to try and clear the condition If the condition does not clear contact your local dealer for assistance Link LED is Off NetworkcableorEthernet device attached to this port may be defective Verify that the switch and attached device are powered on Be sure the cable is plugged into both the switch and corresponding device Verify that the proper cable type is used and ...

Страница 54: ... where you are sure that all the other components are functioning properly In Band Access You can access the management agent in the switch from anywhere within the attached network using Telnet a Web browser or other network management software tools However you must first configure the switch with a valid IP address subnet mask and default gateway If you have trouble establishing a link to the m...

Страница 55: ...RJ 45 connector are numbered Be sure to hold the connectors in the same orientation when attaching the wires to the pins Figure B 1 RJ 45 Connector Pin Numbers 10BASE T 100BASE TX Pin Assignments Use unshielded twisted pair UTP or shielded twisted pair STP cable for RJ 45 connections 100 ohm Category 3 4 or 5 cable for 10 Mbps connections or 100 ohm Category 5 cable for 100 Mbps connections Also b...

Страница 56: ...owing diagram to support Gigabit Ethernet connections Figure B 2 Straight through Wiring Table B 1 10 100BASE TX MDI and MDI X Port Pinouts Pin MDI Signal Name MDI X Signal Name 1 Transmit Data plus TD Receive Data plus RD 2 Transmit Data minus TD Receive Data minus RD 3 Receive Data plus RD Transmit Data plus TD 6 Receive Data minus RD Transmit Data minus TD 4 5 7 8 Not used Not used Note The and...

Страница 57: ...abled for any RJ 45 port on these switches you can use either straight through or crossover cable to connect to any device type You must connect all four wire pairs as shown in the following diagram to support Gigabit Ethernet connections Figure B 3 Crossover Wiring White Orange Stripe Orange White Green Stripe 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 EIA TIA 568B RJ 45 Wiring Standard 10 100BASE TX Crosso...

Страница 58: ...onnections or any new cable installations Category 5e enhanced Category 5 or Category 6 cable should be used The Category 5e specification includes test parameters that are only recommendations for Category 5 Therefore the first step in preparing existing Category 5 cabling for running 1000BASE T is a simple test of the cable installation to be sure that it complies with the IEEE 802 3ab standards...

Страница 59: ...allation does not meet one of the test parameters for 1000BASE T there are basically three measures that can be applied to try and correct the problem 1 Replace any Category 5 patch cables with high performance Category 5e or Category 6 cables 2 Reduce the number of connectors used in the link 3 Reconnect some of the connectors in the link Fiber Standards The current TIA Telecommunications Industr...

Страница 60: ...500mA USB 2 0 cable should not exceed 5 meters for 12 Mbps connections or 3 meters for 1 5 Mbps connections Standard USB cable has an A series connector and consists of one 20 28 AWG wire pair for power and one 28 AWG twisted pair for data The cable has a connector shield and an overall jacket Table B 3 USB Port Pinouts Pin Signal Name Wire Color 1 VCC Red 2 Data White 3 Data Green 4 GND Black The...

Страница 61: ... XFP transceiver slot 100 1000 10000 Mbps full duplex Management Port 10 100BASE TX RJ 45 connector auto MDI X Alarm Port DB 15 connector 4 inputs local choice 2 outputs Major and minor mechanical environmental alarms Buffer Architecture 2 Mbytes Aggregate Bandwidth 88 1 Gbps without expansion modules Switching Database 16K MAC address entries 1K static MAC addresses 255 multicast groups LEDs Syst...

Страница 62: ...wo expansion modules Maximum Current 2 0 A 38 VDC with two expansion modules 1 0 A 75 VDC with two expansion modules 0 8 A 110 VAC with two expansion modules 0 4 A 240 VAC with two expansion modules Switch Features Forwarding Mode Store and forward Throughput Wire speed Flow Control Full Duplex IEEE 802 3x Half Duplex Back pressure Management Features In Band Management Web Telnet SSH or SNMP mana...

Страница 63: ...panning Tree Protocol IEEE 802 1s Multiple Spanning Tree Protocol IEEE 802 1p Priority Tags IEEE 802 1Q Virtual LAN IEEE 802 1v Protocol based VLANs IEEE 802 3ac VLAN tagging ISO IEC 8802 3 CSMA CD Compliances CE Mark Emissions FCC Class A Industry Canada Class A EN 50081 1 EN55022 CISPR 22 Class A EN 60555 2 Class A EN 60555 3 EN 61000 3 2 3 VCCI Class A C Tick AS NZS CISPR 22 Class A 89 336 EEC ...

Страница 64: ...ender Module XFP Slots 1 10 Gigabit XFP Communication Speed 10 Gbps Communication Mode Full duplex Network Interface XFP slot Standards IEEE 802 3ae 10 Gigabit Ethernet XFP Transceiver Support 10GBASE SR Duplex fiber Single mode LC connector 10GBASE LR Duplex fiber Single mode LC connector 10GBASE ER Duplex fiber Single mode LC connector ...

Страница 65: ...ernet over two strands of 50 125 62 5 125 or 9 125 micron core fiber cable 1000BASE SX IEEE 802 3z specification for Gigabit Ethernet over two strands of 50 125 or 62 5 125 micron core fiber cable 1000BASE T IEEE 802 3ab specification for Gigabit Ethernet over 100 ohm Category 5 5e or 6 twisted pair cable using all four wire pairs 10GBASE ER IEEE 802 3ae specification for 10 Gigabit Ethernet over ...

Страница 66: ... in which packets transmitted over the cable interfere with each other Their interference makes both signals unintelligible Collision Domain Single CSMA CD LAN segment CSMA CD CSMA CD Carrier Sense Multiple Access Collision Detect is the communication method employed by Ethernet Fast Ethernet or Gigabit Ethernet End Station A workstation server or other device that does not forward traffic Etherne...

Страница 67: ...rnet Now incorporated in IEEE 802 3 2005 IEEE 802 3ae Defines the physical layer specifications for 10 Gigabit Ethernet IEEE 802 3u Defines CSMA CD access method and physical layer specifications for 100BASE TX Fast Ethernet Now incorporated in IEEE 802 3 2005 IEEE 802 3z Defines CSMA CD access method and physical layer specifications for 1000BASE Gigabit Ethernet Now incorporated in IEEE 802 3 20...

Страница 68: ...5 Connector A connector for twisted pair wiring Small Form Factor Pluggable SFP A multisource compliance aggrement for pluggable fiber optic slots and modules for 1000BASE SX 1000BASE LX and 1000BASE LH tranceivers Switched Ports Ports that are on separate collision domains or LAN segments TIA Telecommunications Industry Association Transmission Control Protocol Internet Protocol TCP IP Protocol s...

Страница 69: ...Glossary 5 Glossary XFP See 10 Gigabit Small Form Factor Pluggable XFP ...

Страница 70: ...Glossary Glossary 6 ...

Страница 71: ...2 2 first level aggregation switch 2 3 management connections 2 4 private VLAN connections 2 5 uplink connections 2 3 B brackets attaching 3 3 buffer size C 1 C cable Ethernet cable compatibility 3 1 labeling and connection records 4 7 lengths 4 6 cleaning fiber terminators 4 3 4 4 compliances EMC C 3 safety C 4 connectivity rules 10 Gbps 4 6 10 Mbps 4 7 100 Mbps 4 7 1000 Mbps 4 6 console port 1 3...

Страница 72: ...les 2 2 connections 4 1 O optional module installation 3 5 out of band management 1 2 P package contents 3 2 pin assignments B 1 1000BASE T B 4 10BASE T 100BASE TX B 1 alarm port 3 11 console port 3 10 ports connecting to 4 1 power connecting to AC supply 3 9 connecting to DC supply 3 8 indicators 1 5 modules 1 6 problems troubleshooting A 1 R RJ 45 port connections 4 1 pinouts B 4 rubber foot pad...

Страница 73: ...Index Index 3 switch indicators A 1 Telnet A 2 twisted pair connections 4 1 W web based management 1 2 X XFP slots 1 3 transceiver connections 4 4 ...

Страница 74: ...Index Index 4 ...

Страница 75: ......

Страница 76: ...SM24 1000SFP AH E112009 DT R01 ...

Отзывы: