CSMIM/Micro-CS Management Application Guide
19-79
ps_history_buffer
is used with the
telnet
command to indicate how much incoming data a slave
port keeps in a buffer. Incoming data is buffered continuously before,
during, and after the Telnet session. The port must be reset after you
change this parameter value.
redisplay_line
defines the reprint line character for CLI users.
remote_address
contains the IP address for a host at the other end of the serial line. This
parameter works only when the mode parameter is set to
autodetect
,
slip
or
ppp
.
reset_idle_time_on
defines whether input or output resets the idle timer. The idle time is the
time lapse between activity and inactivity at the device. This parameter
works with the
who
command.
Type
Async
Values
0 to 32767
Default
0
Lists
Async Ports, Basic Async Port
Type
Async
Values
+ any character
Default
+
(displays as ^R)
Lists
Async Port, Command_Line_Editing
Type
Async
Values
IP address
Default
0.0.0.0
Lists
Async Port, PPP, SLIP
Type
Async
Values
input or output
Default
input
Lists
Async Port, Idle Timer
Ctrl
Ctrl
R
Содержание CSMIM-T1
Страница 1: ...Title Page CSMIM MICRO CSMANAGEMENTAPPLICATION ADMINISTRATOR S GUIDE ...
Страница 2: ......
Страница 22: ...Preface 10 CSMIM Micro CS Management Application Guide ...
Страница 32: ...Chapter 1 Installing Annex Manager 1 10 CSMIM Micro CS Management Application Guide ...
Страница 54: ...Chapter 2 Window Basics 2 22 CSMIM Micro CS Management Application Guide ...
Страница 74: ...Chapter 3 Working with Annex Manager Windows 3 20 CSMIM Micro CS Management Application Guide ...
Страница 94: ...Chapter 4 Using the Main Window 4 20 CSMIM Micro CS Management Application Guide ...
Страница 138: ...Chapter 8 Setting ISDN Primary Rate Annex Values 8 14 CSMIM Micro CS Management Application Guide ...
Страница 152: ...CSMIM Micro CS Management Application Guide 10 4 Figure 10 2 Reset Parameters Window ...
Страница 168: ...Chapter 12 Using and Creating Parameter Groups 12 8 CSMIM Micro CS Management Application Guide ...
Страница 202: ...Chapter 14 Viewing Creating and Executing Scripts 14 20 CSMIM Micro CS Management Application Guide ...
Страница 220: ...Chapter 15 Comparing and Copying Parameters and Values 15 18 CSMIM Micro CS Management Application Guide ...
Страница 240: ...Chapter 16 Booting and Resetting Annexes 16 20 CSMIM Micro CS Management Application Guide ...
Страница 286: ...Chapter 17 Displaying Status Information 17 46 CSMIM Micro CS Management Application Guide ...
Страница 300: ...Chapter 18 Annex Manager and SNMP 18 14 CSMIM Micro CS Management Application Guide ...