
Booting Annexes
CSMIM/Micro-CS Management Application Guide
16-3
Defining Boot Options
You can choose one of the following
Boot Option
buttons:
❑
Immediate
boots selected Annexes as soon as you activate the
command.
❑
Delayed
accepts a
Boot Time
at which the boot will occur. You can
enter more than one delayed request. However, if you enter a
second request for a time earlier than an existing request, the
selected Annexes will boot at the earlier time and all other
existing boot requests will be deleted.
❑
Dump
saves the current image to the address you enter in the
Pref Dump Addr
field.
❑
Diagnostic
places an Annex in test mode and begins diagnostic
tests. When these tests end, the Annex is in ROM Monitor
mode and cannot respond to Annex Manager requests until
you boot it.
❑
Abort
cancels all delayed boot requests.
❑
Quiet
boots the Annexes you selected without sending a
warning message to users.
❑
Save In Flash
loads the boot image and saves it in flash memory.
When you reboot, you can use the image in the flash memory
rather than an image from a server on the network.
For
Boot Options
other than
Quiet
, Annex Manager sends a
status message to all terminals connected to the
Annexes you are booting. Each message contains Annex
names and an indication of shutdown. For
Delayed
, the message
includes the boot time. For
Abort
, the message indicates
cancellation.
Using Text Fields
The window’s text fields control the
Boot
command’s addresses, source,
time, image, and message to users:
❑
Pref Load Addr
stores the address from which the boot command
will load the image.
Содержание CSMIM-T1
Страница 1: ...Title Page CSMIM MICRO CSMANAGEMENTAPPLICATION ADMINISTRATOR S GUIDE ...
Страница 2: ......
Страница 22: ...Preface 10 CSMIM Micro CS Management Application Guide ...
Страница 32: ...Chapter 1 Installing Annex Manager 1 10 CSMIM Micro CS Management Application Guide ...
Страница 54: ...Chapter 2 Window Basics 2 22 CSMIM Micro CS Management Application Guide ...
Страница 74: ...Chapter 3 Working with Annex Manager Windows 3 20 CSMIM Micro CS Management Application Guide ...
Страница 94: ...Chapter 4 Using the Main Window 4 20 CSMIM Micro CS Management Application Guide ...
Страница 138: ...Chapter 8 Setting ISDN Primary Rate Annex Values 8 14 CSMIM Micro CS Management Application Guide ...
Страница 152: ...CSMIM Micro CS Management Application Guide 10 4 Figure 10 2 Reset Parameters Window ...
Страница 168: ...Chapter 12 Using and Creating Parameter Groups 12 8 CSMIM Micro CS Management Application Guide ...
Страница 202: ...Chapter 14 Viewing Creating and Executing Scripts 14 20 CSMIM Micro CS Management Application Guide ...
Страница 220: ...Chapter 15 Comparing and Copying Parameters and Values 15 18 CSMIM Micro CS Management Application Guide ...
Страница 240: ...Chapter 16 Booting and Resetting Annexes 16 20 CSMIM Micro CS Management Application Guide ...
Страница 286: ...Chapter 17 Displaying Status Information 17 46 CSMIM Micro CS Management Application Guide ...
Страница 300: ...Chapter 18 Annex Manager and SNMP 18 14 CSMIM Micro CS Management Application Guide ...