CSMIM/Micro-CS Management Application Guide
19-61
name_server_1
defines the type of name service used with the primary name server. This
parameter works only when you specify a host in
pref_name1_addr
.
name_server_2
defines the type of name service used with the secondary name server.
The Annex uses this service when the service specified in
name_server_1
is
not available. This parameter works only when you specify a host in
pref_name2_addr
.
nameserver_broadcast
defines whether the Annex broadcasts a name server request if the
preferred name servers do not respond.
need_dsr
allows an Annex to use the DSR (Data Set Ready) signal to determine
whether a device is attached to the corresponding asynchronous line. The
Annex will not allow connection to a slave line port and will not activate CLI
until the DSR signal is active. If DSR is deactivated, the connection to a
slave line is terminated and CLI is deactivated.
If you choose
disabled
, the DSR signal is not required to connect to a slave
line, and is not required to activate a CLI line. DSR is always considered
Type
Annex
Values
dns, ien_116, none
Default
none
Lists
Annex Only, Nameserver
Type
Annex
Values
dns, ien_116, none
Default
none
Lists
Annex Only, Nameserver
Type
Annex
Values
enabled or disabled
Default
disabled
Lists
Annex Only, Modem
Содержание CSMIM-T1
Страница 1: ...Title Page CSMIM MICRO CSMANAGEMENTAPPLICATION ADMINISTRATOR S GUIDE ...
Страница 2: ......
Страница 22: ...Preface 10 CSMIM Micro CS Management Application Guide ...
Страница 32: ...Chapter 1 Installing Annex Manager 1 10 CSMIM Micro CS Management Application Guide ...
Страница 54: ...Chapter 2 Window Basics 2 22 CSMIM Micro CS Management Application Guide ...
Страница 74: ...Chapter 3 Working with Annex Manager Windows 3 20 CSMIM Micro CS Management Application Guide ...
Страница 94: ...Chapter 4 Using the Main Window 4 20 CSMIM Micro CS Management Application Guide ...
Страница 138: ...Chapter 8 Setting ISDN Primary Rate Annex Values 8 14 CSMIM Micro CS Management Application Guide ...
Страница 152: ...CSMIM Micro CS Management Application Guide 10 4 Figure 10 2 Reset Parameters Window ...
Страница 168: ...Chapter 12 Using and Creating Parameter Groups 12 8 CSMIM Micro CS Management Application Guide ...
Страница 202: ...Chapter 14 Viewing Creating and Executing Scripts 14 20 CSMIM Micro CS Management Application Guide ...
Страница 220: ...Chapter 15 Comparing and Copying Parameters and Values 15 18 CSMIM Micro CS Management Application Guide ...
Страница 240: ...Chapter 16 Booting and Resetting Annexes 16 20 CSMIM Micro CS Management Application Guide ...
Страница 286: ...Chapter 17 Displaying Status Information 17 46 CSMIM Micro CS Management Application Guide ...
Страница 300: ...Chapter 18 Annex Manager and SNMP 18 14 CSMIM Micro CS Management Application Guide ...