Chapter 19 Annex Parameters
19-66
CSMIM/Micro-CS Management Application Guide
phone_number
defines the default phone number used with demand dialing on the port.
The number you enter must be compatible with the modem connected to
the port.
port_modem_config
sets other parameters for a specific modem configuration. Each value you
choose here sets values in the
mode
,
port_type
,
speed
,
control_lines
,
input_flow_control
,
output_flow_control
,
need_dsr
,
bidirectional_modem
, and
broadcast
parameters. The
dialinautobaud
and
dialinoutautobaud
selections set the
autobaud
parameter in addition to those listed above. The following list includes the
parameter values that will be set. You can use this parameter only for
RA6100, Cabletron CSMIM-T1, and Cabeltron MODMIM products.
❑
None
sets
mode
to
cli
,
port_type
to
hardwired
,
speed
to
9600
,
control_lines
to
none
,
input_flow_control
to
none
,
output_flow_control
to
start/stop
,
need_dsr
to
disabled
,
bidirectional_modem
to
disabled
, and
broadcast_direction
to
port
.
❑
Dialinautobaud
sets
mode
to
cli
,
port_type
to
dialin
,
autobaud
to
enabled
,
speed
to
115200
(or the highest speed that the hardware
supports),
control_lines
to
both
,
input_flow_control
to
eia
,
output_flow_control
to
eia
,
need_dsr
to
enabled
,
bidirectional_modem
to
disabled
, and
broadcast_direction
to
port
.
❑
Dialin
sets
mode
to
cli
,
port_type
to
dialin
,
speed
to
115200
(or the
highest speed that the hardware supports),
control_lines
to
both
,
input_flow_control
to
eia
,
output_flow_control
to
eia
,
need_dsr
to
enabled
,
bidirectional_modem
to
disabled
, and
broadcast_direction
to
port
.
❑
Dialinoutautobaud
sets
mode
to
adaptive,
autobaud
to
enabled
,
port_type
to
dialin
,
speed
to
115200
(or the highest speed that the hardware
supports),
control_lines
to
both
,
input_flow_control
to
eia
,
output_flow_control
to
eia
,
need_dsr
to
disabled
,
bidirectional_modem
to
enabled
, and
broadcast_direction
to
port
.
❑
Dialinout
sets
mode
to
adaptive,
port_type
to
dialin
,
speed
to
115200
(or
the highest speed that the hardware supports),
control_lines
to
Type
Async
Values
32 characters
Default
“ “ (null string)
Lists
Async Port, PPP, SLIP
Содержание CSMIM-T1
Страница 1: ...Title Page CSMIM MICRO CSMANAGEMENTAPPLICATION ADMINISTRATOR S GUIDE ...
Страница 2: ......
Страница 22: ...Preface 10 CSMIM Micro CS Management Application Guide ...
Страница 32: ...Chapter 1 Installing Annex Manager 1 10 CSMIM Micro CS Management Application Guide ...
Страница 54: ...Chapter 2 Window Basics 2 22 CSMIM Micro CS Management Application Guide ...
Страница 74: ...Chapter 3 Working with Annex Manager Windows 3 20 CSMIM Micro CS Management Application Guide ...
Страница 94: ...Chapter 4 Using the Main Window 4 20 CSMIM Micro CS Management Application Guide ...
Страница 138: ...Chapter 8 Setting ISDN Primary Rate Annex Values 8 14 CSMIM Micro CS Management Application Guide ...
Страница 152: ...CSMIM Micro CS Management Application Guide 10 4 Figure 10 2 Reset Parameters Window ...
Страница 168: ...Chapter 12 Using and Creating Parameter Groups 12 8 CSMIM Micro CS Management Application Guide ...
Страница 202: ...Chapter 14 Viewing Creating and Executing Scripts 14 20 CSMIM Micro CS Management Application Guide ...
Страница 220: ...Chapter 15 Comparing and Copying Parameters and Values 15 18 CSMIM Micro CS Management Application Guide ...
Страница 240: ...Chapter 16 Booting and Resetting Annexes 16 20 CSMIM Micro CS Management Application Guide ...
Страница 286: ...Chapter 17 Displaying Status Information 17 46 CSMIM Micro CS Management Application Guide ...
Страница 300: ...Chapter 18 Annex Manager and SNMP 18 14 CSMIM Micro CS Management Application Guide ...