
CSMIM/Micro-CS Management Application Guide
19-63
newline_terminal
interprets carriage returns and line feeds for CLI. When you enter
disabled
,
a carriage return or a line feed terminates the input line and a carriage
return followed by a line feed terminates output lines. When you enter
enabled
, a line feed terminates both the input and the output lines.
node_id
contains the address an Annex tries to acquire at the start of an AppleTalk
session. If the address you enter here is in use, the Annex must acquire a
new node ID. This new ID is stored in non-volatile RAM. Each ID has two
parts, separated by a dot.
option_key
enables AppleTalk-specific functions and parameters, the CLI
tn3270
command, active RIP, dial-out routing, filtering, and IPX. These features
are available separately or in any combination. Each Annex requires a
unique key value for the features you choose. You must contact your
supplier to obtain the key value.
output
_flow_control
defines the method that a device uses to start or stop output from an Annex.
You can choose:
❑
none
to disable flow control.
❑
start/stop
to designate flow control by recognizing xon and xoff
characters.
Type
Annex
Values
enabled or disabled
Default
disabled
Lists
Async Port, Command Line Editing
Type
Annex
Values
0 to 65534.255
Default
0.0
Lists
Annex Only, AppleTalk
Lists
Annex
Values
option key value from your supplier
Default
n/a
Lists
Annex Only, Basic Annex, AppleTalk, IPX
Содержание CSMIM-T1
Страница 1: ...Title Page CSMIM MICRO CSMANAGEMENTAPPLICATION ADMINISTRATOR S GUIDE ...
Страница 2: ......
Страница 22: ...Preface 10 CSMIM Micro CS Management Application Guide ...
Страница 32: ...Chapter 1 Installing Annex Manager 1 10 CSMIM Micro CS Management Application Guide ...
Страница 54: ...Chapter 2 Window Basics 2 22 CSMIM Micro CS Management Application Guide ...
Страница 74: ...Chapter 3 Working with Annex Manager Windows 3 20 CSMIM Micro CS Management Application Guide ...
Страница 94: ...Chapter 4 Using the Main Window 4 20 CSMIM Micro CS Management Application Guide ...
Страница 138: ...Chapter 8 Setting ISDN Primary Rate Annex Values 8 14 CSMIM Micro CS Management Application Guide ...
Страница 152: ...CSMIM Micro CS Management Application Guide 10 4 Figure 10 2 Reset Parameters Window ...
Страница 168: ...Chapter 12 Using and Creating Parameter Groups 12 8 CSMIM Micro CS Management Application Guide ...
Страница 202: ...Chapter 14 Viewing Creating and Executing Scripts 14 20 CSMIM Micro CS Management Application Guide ...
Страница 220: ...Chapter 15 Comparing and Copying Parameters and Values 15 18 CSMIM Micro CS Management Application Guide ...
Страница 240: ...Chapter 16 Booting and Resetting Annexes 16 20 CSMIM Micro CS Management Application Guide ...
Страница 286: ...Chapter 17 Displaying Status Information 17 46 CSMIM Micro CS Management Application Guide ...
Страница 300: ...Chapter 18 Annex Manager and SNMP 18 14 CSMIM Micro CS Management Application Guide ...