Chapter 19 Annex Parameters
19-8
CSMIM/Micro-CS Management Application Guide
CallDef_at_nodeid
specifies the Appletalk hint used by an ISDN Primary Rate Annex. You can
enter an ID in decimal or hexadecimal notation. Each ID has two parts
separated by a dot:
❑
A network address ranges from 0 to 65534 (0x0000 to
0xFFFE).
❑
A node address ranges from 0 to 255 (0x00 to 0xFE).
For example,
191.253
,
0x00BF.253
and
191.0xFD
designate the same address.
CallDef_at_security
turns on ACP service for an AppleTalk session. When you choose
enabled
for this parameter and for
enable_security
, the ISDN Primary Rate Annex uses
ACP to get security information about the client, including authentication,
logging, and zone access information. If you choose
disabled
, the ISDN
Primary Rate Annex uses only local security.
CallDef_attn
_string
defines a control character sequence that returns users to the CLI prompt.
Users can define a temporary control character sequence using the CLI
stty attn
command.
Type
Annex
Values
0 to 65534.255
Default
0.0
Lists
Annex Only, AppleTalk, Call Defaults
Type
Annex
Values
enabled or disabled
Default
disabled
Lists
Annex Only, AppleTalk, Call Defaults
Type
Annex
Value
+ any character, up to 16 characters
Default
“ “ (null string) or
+
(for vcli connections)
Lists
Annex Only, Cmd LIne Editing, Modem, Modem Internal,
Call Defaults
Ctrl
Ctrl
A
Содержание CSMIM-T1
Страница 1: ...Title Page CSMIM MICRO CSMANAGEMENTAPPLICATION ADMINISTRATOR S GUIDE ...
Страница 2: ......
Страница 22: ...Preface 10 CSMIM Micro CS Management Application Guide ...
Страница 32: ...Chapter 1 Installing Annex Manager 1 10 CSMIM Micro CS Management Application Guide ...
Страница 54: ...Chapter 2 Window Basics 2 22 CSMIM Micro CS Management Application Guide ...
Страница 74: ...Chapter 3 Working with Annex Manager Windows 3 20 CSMIM Micro CS Management Application Guide ...
Страница 94: ...Chapter 4 Using the Main Window 4 20 CSMIM Micro CS Management Application Guide ...
Страница 138: ...Chapter 8 Setting ISDN Primary Rate Annex Values 8 14 CSMIM Micro CS Management Application Guide ...
Страница 152: ...CSMIM Micro CS Management Application Guide 10 4 Figure 10 2 Reset Parameters Window ...
Страница 168: ...Chapter 12 Using and Creating Parameter Groups 12 8 CSMIM Micro CS Management Application Guide ...
Страница 202: ...Chapter 14 Viewing Creating and Executing Scripts 14 20 CSMIM Micro CS Management Application Guide ...
Страница 220: ...Chapter 15 Comparing and Copying Parameters and Values 15 18 CSMIM Micro CS Management Application Guide ...
Страница 240: ...Chapter 16 Booting and Resetting Annexes 16 20 CSMIM Micro CS Management Application Guide ...
Страница 286: ...Chapter 17 Displaying Status Information 17 46 CSMIM Micro CS Management Application Guide ...
Страница 300: ...Chapter 18 Annex Manager and SNMP 18 14 CSMIM Micro CS Management Application Guide ...