8
Shutting down the heating system
Logano plus GB312 - Technical specifications are subject to change without prior notice
55
8
Shutting down the heating system
8.1
Shutting down the heating system using the programmer
Turn off the heating system on the Logamatic BC10 basic
control unit. When the Logamatic BC10 basic control unit
is switched off, the burner is automatically shut down at
the same time. For more detailed information about using
the Logamatic BC10 basic control unit, refer to Section 7,
page 41.
V
Switch off the heating system with the BC10 ON/OFF
switch.
V
Turn off the main isolating valve.
Fig. 50 Logamatic BC10 basic control unit
8.2
Shutting down the heating system in an emergency
8.2.1
Action in an emergency
Explain to the customer what to do in an emergency, e.g.
a fire.
V
Never put yourself at risk of fatal injury. Your own safety
must always take the highest priority.
V
Turn off the main isolating valve.
V
Disconnect the heating system from the electrical
power supply by means of the emergency stop switch
or the appropriate circuit-breaker.
Caution:
Risk of system damage due to
freezing.
If the heating system has been switched off,
it may freeze up at sub-zero temperatures.
V
Protect the heating system from freezing
when there is a danger of frost. To do so,
drain the water out of the heating system
from its lowest point. When doing so, the
vent at the highest point of the system
must be open.
7 747 010 720-38.2RS
90
130
100
120
110
Eco
140
Aut
90
110
130
150
170
190
Aut
The circuit-breaker for the boiler room or the
heating emergency stop switch should only
be used to switch off the heating system in an
emergency.