Recommissioning the heating system
Logano plus GB312 - Technical specifications are subject to change without prior notice
46
7.9.2
Boiler intended to be used with RC35
V
Use the RC35 programming unit.
7.9.3
Continuing commissioning procedure with
RC35
V
Turn the "maximum boiler temperature" control knob
and "hot water temperature" control knob to 0.
This ensures that the boiler does not start up at this
point (no demand for heat).
V
Set the ON/OFF switch on the basic control unit to
position “1”.
This turns on the entire heating system. When first
commissioned, the display briefly shows a flashing "-"
before showing fault message "4A"-"700". The fault
message “4A”-“700” is displayed because the burner
is at fault setting when delivered.
V
Wait about 1 minute while the EMS connection to the
RC35 programming unit (available separately) is estab-
lished.
V
Press the “Reset” button on the BC10. The status dis-
play on the BC10 lights up and the current boiler tem-
perature in °F is shown.
If fault message”A11” appears, you must set the date and
time on the RC35 programming unit. Only then will the
current boiler water temperature be displayed.
Fig. 41 Logamatic BC10 basic control unit
1
On/off switch
2
Control knob for "hot water temperature"
3
“Reset” button
4
"Engineer" button for flue gas test
5
"Status display" button
6
Display
7
“Burner (On/Off)” LED
8
Control knob for "maximum boiler temperature" in heating
mode
Before continuing the commissioning procedure, set the
correct parameters on the RC35 programming unit. In
particular the DHW configuration (central heating pump
and cylinder charging pump) must be adjusted correctly
to ensure the heating system works properly. Refer to the
installation and servicing instructions for the RC35 pro-
gramming unit for information on how to do so.
7.10 Switching on the boiler on the BC10
V
Set the ON/OFF switch on the basic control unit to
position ”1”.
This turns on the entire heating system. The status dis-
play on the basic control unit lights up and shows the
current boiler water temperature in °F.
Fig. 42 Switching on the basic control unit
7 747 010 720-37.1RS
90
130
100
120
110
Eco
140
Aut
90
110
130
150
170
190
Aut
1
2 3
4
5
6
7
8
7 747 010 720-38.2RS
90
130
100
120
110
Eco
140
Aut
90
110
130
150
170
190
Aut
Содержание Logano plus GB312
Страница 121: ...Logano plus GB312 Technical specifications are subject to change without prior notice 121 Notes ...
Страница 122: ...Logano plus GB312 Technical specifications are subject to change without prior notice 122 Notes ...
Страница 123: ...Logano plus GB312 Technical specifications are subject to change without prior notice 123 Notes ...