D AWHP 4.5 MR
E AWHP 6 MR-3
F AWHP 8 MR-2 / AWHP 11 MR-2 / AWHP 16 MR-2 AWHP 11
TR-2 / AWHP 16 TR-2
1. Remove the service panel.
2. AWHP 4.5 MR only: remove the earth connection screw from the
appliance and discard.
3. Check the cross-section of the cable used, as well as its protection in
the electric panel.
4. AWHP 4.5 MR only: secure the screw and square washer provided on
the stripped part of the earth wire
.
Danger
The stripped part of the earth wire must be fitted underneath the
washer against the base frame.
5. Connect the earth wire.
Danger
The earth wire must be 10 mm longer than the N and L wires.
6. Connect the cables to the appropriate terminals.
7. Feed the cable into the cable duct and adjust the length of the cable
accordingly. Lock it in position with a cable clamp or a traction arrester
device.
Caution
Danger of electric shock: the length of the conductors between the
traction arrester device and the terminal blocks must be such that
the active conductors are put under tension before the earth
conductor.
Fig.53
MW-1001217-1
1
2
D
E
F
230V~
NEW
4
5
6
7
230V~
L
N
10mm
7
7
1
1
6 Installation
50
AWHP-2 PBS-i
7706696 - v04 - 11102018
Содержание PBS-i WH2 Series
Страница 45: ...12 Appendix 7706698 v04 17102018 AWHP 2 PBS i 45 ...
Страница 46: ...12 Appendix 46 AWHP 2 PBS i 7706698 v04 17102018 ...
Страница 69: ...3 4 Electrical diagram Fig 12 MW 5000747 5 3 Technical specifications 7706696 v04 11102018 AWHP 2 PBS i 21 ...
Страница 154: ...12 Decommissioning and disposal 106 AWHP 2 PBS i 7706696 v04 11102018 ...
Страница 178: ...1 Spare parts 22 AWHP 2 PBS i 7706697 v04 11102018 ...