Product name
AWHP-2 PBS-i
AWHP 8 MR-2
AWHP-2 PBS-i
AWHP 11
MR-2
AWHP 11
TR-2
AWHP-2 PBS-i
AWHP 16
MR-2
AWHP 16
TR-2
Annual energy consumption under colder con
ditions
Q
HE
kWh
4621
3804
5684
Annual energy consumption under warmer
conditions
Q
HE
kWh
1904
2580
4120
Rated air flow rate, outdoors for air-to-water
heat pumps
—
m
3
/h
3300
6000
6000
(1) The rated heat output
Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
(2) If
Cdh is not determined by measurement, the default degradation coefficient is Cdh = 0.9.
See
The back cover for contact details.
3.2.4
Circulating pump
Important
The benchmark for the most efficient circulating pumps is EEI ≤
0.20.
3 Technical specifications
7706698 - v04 - 17102018
AWHP-2 PBS-i
15