Product name
AWHP-2 PBS-i
AWHP 4.5 MR
AWHP-2 PBS-i
AWHP 6 MR-3
Annual energy consumption under warmer
conditions
Q
HE
kWh
1249
1492
Rated air flow rate, outdoors for air-to-water
heat pumps
—
m
3
/h
2100
2100
(1) The rated heat output
Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
(2) If
Cdh is not determined by measurement, the default degradation coefficient is Cdh = 0.9.
Tab.11 Technical parameters for heat pump combination heaters (parameters declared for medium-temperature application)
Product name
AWHP-2 PBS-i
AWHP 8 MR-2
AWHP-2 PBS-i
AWHP 11
MR-2
AWHP 11
TR-2
AWHP-2 PBS-i
AWHP 16
MR-2
AWHP 16
TR-2
Air-to-water heat pump
Yes
Yes
Yes
Water-to-water heat pump
No
No
No
Brine-to-water heat pump
No
No
No
Low-temperature heat pump
No
No
No
Equipped with a supplementary heater
Yes
Yes
Yes
Heat pump combination heater
No
No
No
Rated heat output under average conditions
Prated
kW
6
6
9
Rated heat output under colder conditions
Prated
kW
6
4
7
Rated heat output under warmer conditions
Prated
kW
6
8
13
Declared capacity for heating for part load at an
indoor temperature of 20 °C and outdoor temper
ature
T
j
T
j
= -7 °C
Pdh
kW
5.6
5.9
9.0
T
j
= +2 °C
Pdh
kW
2.9
5.3
6.5
T
j
= +7 °C
Pdh
kW
6.4
9.0
12.9
T
j
= +12 °C
Pdh
kW
4.3
7.7
10.0
T
j
= bivalent temperature
Pdh
kW
5.2
6.3
8.8
T
j
= operation limit temperature
Pdh
kW
5.2
6.3
8.8
Bivalent temperature
T
biv
°C
-10
-10
-10
Cdh
—
1.0
1.0
1.0
Seasonal space heating energy efficiency under
average conditions
ƞ
s
%
129
125
121
Seasonal space heating energy efficiency under
colder conditions
ƞ
s
%
119
113
113
Seasonal space heating energy efficiency under
warmer conditions
ƞ
s
%
169
167
161
Declared coefficient of performance or primary
energy ratio for part load at an indoor tempera
ture of 20 °C and outdoor temperature
T
j
T
j
= -7 °C
COPd
-
1.95
1.87
1.85
T
j
= +2 °C
COPd
-
3.22
3.17
3.02
T
j
= +7 °C
COPd
-
4.57
4.54
4.34
T
j
= +12 °C
COPd
-
6.55
6.19
5.75
T
j
= bivalent temperature
COPd
-
1.70
1.20
1.35
T
j
= operation limit temperature
COPd
-
1.70
1.20
1.35
Operation limit temperature for air-to-water
heat pumps
TOL
°C
-10
-10
-10
Heating water operating limit temperature
WTOL
°C
60
60
60
Electrical power consumption
3 Technical specifications
14
AWHP-2 PBS-i
7706696 - v04 - 11102018
Содержание PBS-i WH2 Series
Страница 45: ...12 Appendix 7706698 v04 17102018 AWHP 2 PBS i 45 ...
Страница 46: ...12 Appendix 46 AWHP 2 PBS i 7706698 v04 17102018 ...
Страница 69: ...3 4 Electrical diagram Fig 12 MW 5000747 5 3 Technical specifications 7706696 v04 11102018 AWHP 2 PBS i 21 ...
Страница 154: ...12 Decommissioning and disposal 106 AWHP 2 PBS i 7706696 v04 11102018 ...