3. Select the number corresponding to the installation type by pressing
the or key. Selecting the installation type enables automatic
configuration of the parameters required for the control panel to
operate correctly (gradient, maximum circuit temperature, etc.). For a
configuration which differs from those proposed here, press the
h
key on the control panel and configure the parameters manually.
Installation type
No.
One direct heating circuit
01
One direct heating circuit and one domestic hot water
tank
02
One direct heating circuit and one underfloor heating cir
cuit with mixing valve
03
One direct heating circuit and one domestic hot water
tank and one underfloor heating circuit with mixing valve
04
One direct underfloor heating circuit
05
One direct underfloor heating circuit and one domestic
hot water tank
06
4. Confirm the selection by pressing the
key.
5. Set the heating curve.
The main parameters are set.
6. Apply the required settings based on the additional options connected.
7.5
Checking the minimum flow
Heating installations must be able to guarantee a minimum flow rate at all
times. If the flow rate is too low, the heat pump may shut itself down for its
own protection; the heating, cooling and domestic hot water functions are
then no longer guaranteed.
1. Check the minimum flow rate as defined by the HP010 parameter.
See
The flow rate value within the installation can be read using the
AM056 parameter.
2. Set the differential pressure valves to guarantee an optimum flow rate
in the installation when thermostatic valves are closed. The optimum
flow rate is defined by the HP069 parameter.
7.6
Final instructions for commissioning
1. If necessary, deactivate the heat pump's domestic hot water mode.
2. Simulate a heat demand to start up heating mode.
3. Check start-up of the outdoor unit and the back-ups connected.
4. Check the flow rate in the installation in comparison to the minimum
flow rate.
5. Put the heat pump in shut-down/frost protection mode.
6. After about 10 minutes, vent the air in the heating system.
7. Check the hydraulic pressure on the user interface. If necessary, top
up the water level in the heating system.
8. Check the fouling level of the filter(s) inside and outside the heat
pump. If necessary, clean the filter(s).
9. Restart the heat pump and deactivate shutdown/frost protection mode
Fig.69
MW
-1
0
0
0
6
7
6
-1
Fig.70
01
MW-10001142-2
19°
+
02
19°
+
+
03
19°
+
+
04
19°
+
+
+
05
19°
+
06
19°
+
+
7 Commissioning
7706696 - v04 - 11102018
AWHP-2 PBS-i
61
Содержание PBS-i WH2 Series
Страница 45: ...12 Appendix 7706698 v04 17102018 AWHP 2 PBS i 45 ...
Страница 46: ...12 Appendix 46 AWHP 2 PBS i 7706698 v04 17102018 ...
Страница 69: ...3 4 Electrical diagram Fig 12 MW 5000747 5 3 Technical specifications 7706696 v04 11102018 AWHP 2 PBS i 21 ...
Страница 154: ...12 Decommissioning and disposal 106 AWHP 2 PBS i 7706696 v04 11102018 ...
Страница 178: ...1 Spare parts 22 AWHP 2 PBS i 7706697 v04 11102018 ...