6.7.6
Connecting the cables to the PCBs
Keyed connectors are present on different terminal blocks as standard.
Use these to connect the cables to the PCBs If there are no connectors on
the terminal block to be used, use the connector provided with the kit.
Coloured stickers are provided with certain accessories. Use these to
mark each end of the cable with the same colour before passing the
cables into the cable feed-throughs.
1. Insert and screw down the wires in the corresponding connector
inlets.
2. Insert the connector into the corresponding terminal block.
3. Feed the cable into the cable duct and adjust the length of the cable
accordingly.
4. Lock it in position with a cable clamp or a traction arrester device.
Caution
Danger of electric shock: the length of the conductors between the
traction arrester device and the terminal blocks must be such that
the active conductors are put under tension before the earth
conductor.
6.7.7
Electrically connecting the outdoor unit
Fig.52
MW-1001214-1
1
2
1
2
L1 L2 L3
N
S1 S2 S3
1
2
A
B
C
1 Power supply
2 Communication bus
A AWHP 4.5 MR
B AWHP 6 MR-3 / AWHP 8 MR-2 / AWHP 11 MR-2 /
AWHP 16 MR-2
C AWHP 11 TR-2 / AWHP 16 TR-2
Fig.51
MW-6000148-2
1
2
6 Installation
7706696 - v04 - 11102018
AWHP-2 PBS-i
49
Содержание PBS-i WH2 Series
Страница 45: ...12 Appendix 7706698 v04 17102018 AWHP 2 PBS i 45 ...
Страница 46: ...12 Appendix 46 AWHP 2 PBS i 7706698 v04 17102018 ...
Страница 69: ...3 4 Electrical diagram Fig 12 MW 5000747 5 3 Technical specifications 7706696 v04 11102018 AWHP 2 PBS i 21 ...
Страница 154: ...12 Decommissioning and disposal 106 AWHP 2 PBS i 7706696 v04 11102018 ...
Страница 178: ...1 Spare parts 22 AWHP 2 PBS i 7706697 v04 11102018 ...