1. Respect the minimum positioning distances of the outdoor unit from
the wall.
Tab.19 Minimum distances in mm
A
B
C
D
E
F
G
AWHP 4.5 MR
100
500
200
1000
300
150
100
AWHP 6 MR-3
100
500
200
1000
300
150
100
AWHP 8 MR-2
100
500
200
1000
300
150
100
AWHP 11 MR-2
AWHP 11 TR-2
150
1000
300
1500
500
250
200
AWHP 16 MR-2
AWHP 16 TR-2
150
1000
300
1500
500
250
200
6.4.2
Selecting the location of the outdoor unit
To ensure the outdoor unit operates correctly, its location must meet
certain conditions.
1. Decide on the ideal location for the outdoor unit, bearing in mind the
space it requires and any legal directives and in relation to neighbours
as it is a source of noise.
2. Observe the IP24 protection rating of the outdoor unit during
installation.
3. Avoid the following locations:
Prevailing winds. Nothing must obstruct the free circulation of air
around the outdoor unit (intake and outlet).
Close to sleep zones,
Close to a terrace.
Opposite a wall with windows,
Fig.31
MW-5000579-1
E
E
D
D
A
A
B
B
A
A
A
C
C
Max.
500
Max.
500
Fig.32
MW-M001448-2
6 Installation
7706696 - v04 - 11102018
AWHP-2 PBS-i
37
Содержание PBS-i WH2 Series
Страница 45: ...12 Appendix 7706698 v04 17102018 AWHP 2 PBS i 45 ...
Страница 46: ...12 Appendix 46 AWHP 2 PBS i 7706698 v04 17102018 ...
Страница 69: ...3 4 Electrical diagram Fig 12 MW 5000747 5 3 Technical specifications 7706696 v04 11102018 AWHP 2 PBS i 21 ...
Страница 154: ...12 Decommissioning and disposal 106 AWHP 2 PBS i 7706696 v04 11102018 ...
Страница 178: ...1 Spare parts 22 AWHP 2 PBS i 7706697 v04 11102018 ...