ADV
Description of the ADV advanced parameters
Factory setting
DP047
Maximum time allowed to produce Domestic Hot Water
Can be set from 1 to 10 hours
3 (4.5 kW - 6 kW - 8
kW)
2 (11 kW - 16 kW)
DP048
Minimum heating time before Domestic Hot Water production
Can be set from 0 to 10 hours
2
DP055
Enable/disable the TAS protection of the DHW tankCan be set from 0 to 1
0
DP090
Delay for starting the next generator (backup stage) in DHW mode
Can be set from 0 Min to 120 Min
90
DP100
Delay for stopping the next generator (backup stage) in DHW mode
Can be set from 0 Min to 120 Min
2
DP110
Delay for starting the next generator (backup stage) in DHW mode
Can be set from 0 Min to 255 Min
5
DP150
Enable DHW Thermostat function
0 =Off
1 =On
1
DP160
Setpoint for DHW anti legionella
Can be set from 60 °C to 90 °C
Do not modify this setting
65
9.2.5
Installer \EHC–04 and SCB-04 menu
AP : Appliance Parameters = Appliance parameters
Tab.49
Parameter
Description
Factory setting
EHC–04
Factory setting
SCB-04
AP001
Blocking input setting (1: Full blocking, 2: Partial blocking, 3: User
reset locking) BL1:
1 = Full blocking of the installation – frost protection not guaran
teed
2 = Partial blocking of the installation – frost protection active
3 =User reset locking
4 =Backup Relieved
5 =Heat Pump Relieved
6 =HP & backup relieved
7 =High, Low Tariff
8 =Photovoltaic HP Only
9 =PV HP And backup
10 =Smart Grid ready
11= heating/cooling
2
not available
AP028
Defines the type of cooling used.
0 =Off
1 =Active cooling on
2 = Free cooling on, not used
0
1
AP063
Maximum central heating flow temperature setpoint
Can be set from 20 °C to 90 °C
Hydraulic back-
up: 90
Electrical back-
up: 75
not available
AP075
Outdoor temperature neutral band between heating and cooling. The
generator is stopped.
Can be set from 0 to 10 °C
4
4
AP079
Inertia of the building used for heat up speed
Can be set from 0 to 10
0 = 10 hours for a building with low thermal inertia,
= 22 hours for a building with normal thermal inertia,
10 = 50 hours for a building with high thermal inertia.
Modification of the factory setting is only useful in exceptional cases.
3
3
9 Settings
72
AWHP-2 PBS-i
7706696 - v04 - 11102018
Содержание PBS-i WH2 Series
Страница 45: ...12 Appendix 7706698 v04 17102018 AWHP 2 PBS i 45 ...
Страница 46: ...12 Appendix 46 AWHP 2 PBS i 7706698 v04 17102018 ...
Страница 69: ...3 4 Electrical diagram Fig 12 MW 5000747 5 3 Technical specifications 7706696 v04 11102018 AWHP 2 PBS i 21 ...
Страница 154: ...12 Decommissioning and disposal 106 AWHP 2 PBS i 7706696 v04 11102018 ...