8. Construction and installation
8.1. Construction
AQ-X215 is a member of the modular and scalable AQ-200 series, and it includes three (3)
con gurable and modular add-on card slots. As a standard con guration the device includes the CPU
module (which consists of the CPU, a number of inputs and outputs, and the power supply) as well as
one separate voltage measurement module and one separate current measurement module.
The images below present the modules of both the non-optioned model (AQ-X215-XXXXXXX-AAA, on
the left) and the fully optioned model (AQ-X215-XXXXXXX-BCD, on the right).
Figure. 8.1. - 93. Modular construction of AQ-X215.
The modular structure of AQ-X215 allows for scalable solutions for different application requirements.
In non-standard con gurations Slots C, E and F accept all available add-on modules, such as digital I/O
modules, integrated arc protection or another special module.The only difference between the slots
affecting device scalability is that Slot F also supports communication options.
When an add-on module is inserted into the device, the start-up scan searches for modules according
to their type designation code. If the module location or content is not what the device expects, the IED
does not take additional modules into account and instead issues a con guration error message. In
eld upgrades, therefore, the add-on module must be ordered from Arcteq Relays Ltd. or its
representative who can then provide the module with its corresponding unlocking code to allow the
device to operate correctly once the hardware con guration has been upgraded. This also means that
the module's location in the device cannot be changed without updating the device con guration data
which, again, requires the unlocking code.
When an I/O module is inserted into the device, the module location affects the naming of the I/O. The
I/O scanning order in the start-up sequence is as follows: the CPU module I/O, Slot C, Slot E, and Slot
F. This means that the digital input channels DI1, DI2 and DI3 as well as the digital output channels
OUT1, OUT2, OUT3, OUT4 and OUT5 are always located in the CPU module. If additional I/O cards
are installed, their location and card type affect the I/O naming.
AQ-E215
Instruction manual
Version: 2.01
© Arcteq Relays Ltd
166
Содержание AQ-E215
Страница 1: ...AQ E215 Energy management IED Instruction manual ...
Страница 4: ...206 11 Contact and reference information AQ E215 Instruction manual Version 2 01 3 Arcteq Relays Ltd ...
Страница 186: ...Figure 8 13 113 Device installation AQ E215 Instruction manual Version 2 01 185 Arcteq Relays Ltd ...
Страница 206: ... Pt100 1000 Balco500 Ni power module AQ E215 Instruction manual Version 2 01 205 Arcteq Relays Ltd ...