IL1 (ff), IL2 (ff), IL3 (ff), I01 (ff), I02 (ff)
Fundamental frequency current measurement values of phase currents and residual
currents.
IL1 (TRMS), IL2 (TRMS), IL3 (TRMS),
I01 (TRMS), I02 (TRMS)
TRMS current measurement values of phase currents and residual currents.
IL1, IL2, IL3, I01, I02 & 2
nd
h., 3
rd
h.,
4
th
h., 5
th
h., 7
th
h., 9
th
h., 11
th
h., 13
th
h., 15
th
h., 17
th
h., 19
th
h.
Magnitudes of the phase current components: 2
nd
harmonic, 3
rd
harmonic, 4
th
harmonic, 5
th
harmonic 7
th
, harmonic 9
th
, harmonic 11
th
, harmonic 13
th
, harmonic
15
th
, harmonic 17
th
, harmonic 19
th
harmonic current.
I1, I2, I0Z
Positive sequence current, negative sequence current and zero sequence current.
I0CalcMag
Residual current calculated from phase currents.
IL1Ang, IL2Ang, IL3Ang,
I01Ang, I02Ang, I0CalcAng
I1Ang, I2Ang
Angles of each measured current.
Voltages
UL1Mag, UL2Mag, UL3Mag,
UL12Mag, UL23Mag, UL31Mag,
U0Mag, U0CalcMag
Magnitudes of phase voltages, phase-to-phase voltages and residual voltages.
U1 Pos.seq V mag, U2 Neg.seq V mag
Positive and negative sequence voltages.
UL1Ang, UL2Ang, UL3Ang,
UL12Ang, UL23Ang, UL31Ang,
U0Ang, U0CalcAng
Angles of phase voltages, phase-to-phase voltages and residual voltages.
U1 Pos.seq V Ang, U2 Neg.seq V Ang
Positive and negative sequence angles.
Powers
S3PH
P3PH
Q3PH
Three-phase apparent, active and reactive power.
SL1, SL2, SL3,
PL1, PL2, PL3,
QL1, QL2, QL3
Phase apparent, active and reactive powers.
tan 3PH
tan L1
tan L2
tan L3
Tan (φ) of three-phase powers and phase powers.
cos 3PH
cos L1
cos L2
cos L3
Cos (φ) of three-phase powers and phase powers.
Impedances and admittances
RL12, RL23, RL31
XL12, XL23, XL31
RL1, RL2, RL3
XL1, XL2, XL3
Z12, Z23, Z31
ZL1, ZL2, ZL3
Phase-to-phase and phase-to-neutral resistances, reactances and impedances.
Z12Ang, Z23Ang, Z31Ang,
ZL1Ang, ZL2Ang, ZL3Ang
Phase-to-phase and phase-to-neutral impedance angles.
Rseq, Xseq, Zseq
RseqAng, XseqAng, ZseqAng
Positive sequence resistance, reactance and impedance values and angles.
GL1, GL2, GL3, G0
BL1, BL2, BL3, B0
YL1, YL2, YL3, Y0
Conductances, susceptances and admittances.
YL1angle, YL2angle, YL3angle,
Y0angle
Admittance angles.
Others
System f.
Used tracking frequency at the moment.
Ref f1
Reference frequency 1.
AQ-E215
Instruction manual
Version: 2.01
© Arcteq Relays Ltd
156
Содержание AQ-E215
Страница 1: ...AQ E215 Energy management IED Instruction manual ...
Страница 4: ...206 11 Contact and reference information AQ E215 Instruction manual Version 2 01 3 Arcteq Relays Ltd ...
Страница 186: ...Figure 8 13 113 Device installation AQ E215 Instruction manual Version 2 01 185 Arcteq Relays Ltd ...
Страница 206: ... Pt100 1000 Balco500 Ni power module AQ E215 Instruction manual Version 2 01 205 Arcteq Relays Ltd ...