![APRILIA DORSODURO FACTORY ABS 2011 Скачать руководство пользователя страница 152](http://html.mh-extra.com/html/aprilia/dorsoduro-factory-abs-2011/dorsoduro-factory-abs-2011_service-station-manual_2956329152.webp)
Error cause
•
Throttle position, kept by the springs, not within the expected range (at each key ON). The
instrument panel does not indicate the presence of this error even in the ATT status.
Troubleshooting
•
Check if the throttle body and the intake duct are clean. If they are, replace the throttle body.
Front throttle mechanical springs self-acquisition P0161
- test failed.
Error cause
•
Return time of the throttle, kept in position by the springs, not within the expected limits: the
causes can be a deterioration of the performance of the springs or excessive throttle friction
(at each key ON).
Troubleshooting.
•
Check if the throttle body and the intake duct are clean. If they are, replace the throttle body.
Front throttle minimum mechanical position self-acquisition P0162
- test failed.
Error cause
•
Position of the throttle stop not within the expected range (at each key ON).
Troubleshooting.
•
Check if the throttle body and the intake duct are clean. If they are, replace the throttle body.
Detection of front throttle valve Recovery conditions (air Tº,water Tº) P0163
- possible presence
of ice.
Error cause
•
A correct throttle rotation cannot be detected given low ambient and engine temperatures:
some ice may have formed in the duct (at each key ON). The instrument panel does not
indicate the presence of this error even in the ATT status.
Troubleshooting
•
Check that the throttle body is clean and that there is no ice or condensation in the intake
duct. If they are, replace the throttle body.
Front throttle first self-learning NOT performed P0165
- test not carried out.
Error cause
•
The first throttle self-acquisition process has not been successful or has not been carried
out. The instrument panel does not indicate the presence of this error even in the ATT status.
Troubleshooting.
•
Delete errors hindering throttle self-learning.
Front throttle position error P0167
- misalignment between control and activation.
Error cause
Electrical system
DORSODURO FACTORY ABS
ELE SYS - 152
Manuals by Motomatrix / www.motomatrix.co.uk / The Solution For Lost Motorcycle Coded Keys.