Diagnostics Menu Options
179
NetLinx Studio - Instruction Manual
Changing the System Number on a NetLinx Master
1.
Select
Diagnostics > Network Addresses
to access the
Network Addresses
dialog.
2.
At the top of the dialog, specify a new System number in the
System
field.
3.
Click the
Reboot Master
button to reboot the master and accept the new changes. Allow 20-30 seconds for the
master to reboot.
Setting the IP Address for a NetLinx Master
1.
Select
Diagnostics > Network Addresses
to access the
Network Addresses
dialog (see FIG. 260).
2.
At the top of the dialog, enter the specified device’s
System
and
Device
numbers in the text boxes
(range = 0-65535).
3.
Click
Get IP Information
to populate the IP Address fields with the current
Host Name
,
IP Address
,
Subnet
Mask
and
Gateway
assignments.
4.
Click the
Specify IP Address
option button, and enter the new
IP Address
,
Subnet
Mask
and
Gateway
assignments
in the text boxes, as necessary.
5.
Click
Set IP Information
to set the new IP Address assignment.
6.
Click
Reboot Master
to reboot the master and accept the new changes. Allow 20-30 seconds for the master to
reboot.
Setting the DNS Address for a NetLinx Master
1.
Select
Diagnostics > Network Addresses
to access the
Network Addresses
dialog (see FIG. 260).
2.
Enter the specified device’s
System
and
Device
values in the text boxes at the top of the dialog (range = 0-65535).
3.
Click
Get DNS Information
to populate the DNS Address fields with the current
Domain Suffix
,
DNS IP Address
#1
,
DNS IP Address #2
and
DNS IP Address #3
assignments (as applicable).
4.
Edit the DNS Address assignments and/or add new DNS address information as needed.
5.
Click
Set DNS Information
to set the new DNS address assignments.
6.
Click
Reboot Master
to reboot the master and accept the new changes. Allow 20-30 seconds for the master to
reboot.
Changing the IP Address on a NetLinx Device Using DHCP
1.
Select
Diagnostics > Network Addresses
to access the
Network Addresses
dialog (see FIG. 260).
2.
Enter the specified device’s
System
and
Device
values in the text boxes at the top of the dialog (range = 0-65535).
3.
Click
Get IP Information
to populate the IP Address fields with the current
Host Name
and
Gateway
assignments.
4.
Select
Use DHCP
, and enter a new
Host Name
in the field, if necessary.
5.
Click the
Set IP Information
button to set the new Host Name assignment.
6.
Click
Reboot Master
to reboot the master and accept the new changes. Allow 20-30 seconds for the master to
reboot.
Changing the IP Address on a NetLinx Master (Specify IP Address)
1.
Select
Diagnostics > Network Addresses
to access the
Network Addresses
dialog (see FIG. 260).
2.
Enter the specified device’s
System
and
Device
values in the text boxes at the top of the dialog (range = 0-65535).
3.
Click
Get IP Information
to populate the IP Address fields with the current
Host Name
,
IP
Address
,
Subnet
Mask
and
Gateway
assignments.
4.
Select
Specify IP Address
, and enter the new
IP
Address
,
Subnet
Mask
and
Gateway
assignments in the text boxes,
as necessary.
5.
Click
Set IP Information
to set the new IP Address assignment. A message will be displayed indicating that the
Master has accepted the new settings.
6.
Click
Reboot Master
to reboot the Master and accept the new changes. Allow 20-30 seconds for the Master to
reboot.
Содержание NetLinx Studio
Страница 40: ...Working with Projects 28 NetLinx Studio Instruction Manual...
Страница 148: ...Communication Settings 136 NetLinx Studio Instruction Manual...
Страница 160: ...Working with Online Devices 148 NetLinx Studio Instruction Manual...
Страница 178: ...File Transfer Operations 166 NetLinx Studio Instruction Manual...
Страница 208: ...Tools Menu Options 196 NetLinx Studio Instruction Manual...
Страница 229: ...Setting Program Preferences 217 NetLinx Studio Instruction Manual...