File Transfer Operations
163
NetLinx Studio - Instruction Manual
Transfer Errors and Definitions
The following table describe the most common error messages that might be displayed in the Error column of the
Transfer Status Window.
Firmware Transfers
NetLinx Studio provides the ability to transfer KIT and TSK firmware files to a NetLinx or Axcess master controller. To
send firmware files, select
Tools > Firmware Transfers,
then select either
Send to NetLinx Device
, or
Send to Axcess
Device
from the sub-menu.
Sending Firmware to a NetLinx Device (KIT File)
Use the
Firmware Transfers
options in the Tools menu to update the firmware in NetLinx Master Controllers or System
devices. NXI Master Controllers use Kit files for firmware upgrades. A Kit file (*.kit) is a package of several files, all of
which are required to upgrade the firmware, and are available online via www.amx.com.
The Online Tree (Online Tree tab of the Workspace Bar) displays information about each online device,
including the current firmware version.
Before attempting to upgrade the firmware, you must have the appropriate Kit file for your NetLinx Master.
1.
Choose
Tools > Firmware Transfers > Send to NetLinx Device
to open the
Send To NetLinx Device
dialog
(FIG. 243).
Transfer Errors and Definitions
Error String
Meaning
Failure
Generic/unclassified failure.
Success
Generic success.
File does not exist
The file supplied on the cmdline doesn't exist.
Failed to create
temporary file
Couldn't create a required temporary file.
Invalid file type
The file supplied on the cmdline is an unknown file type.
Unknown Error
Generic/unknown error.
File: <filename> does not
exist and cannot be
transferred!
File does not exist at location specified.
File: <filename> is
currently opened by
another application and
cannot be transferred!
This can happen if another application has an exclusive lock on a file.
Nothing to transfer!
[Project Identifier invalid?]
[System Identifier invalid?]
After processing all supplied parameters and options, there was nothing to transfer. That is,
no files could be found or nothing was specified for transfer.
Additionally, if you specified a project identifier and/or a system identifier, you may have
inadvertently requested an empty or nonexistent set of files.
Failed to open workspace! Failed to open the specified workspace.
No APW file
AXW file does not contain an APW.
If for any reason your Kit file transfer should fail, continue to retry the transfer until
you are successful. DO NOT reboot the Master, or change connections until the
transfer is complete. Failure to complete this operation successfully may result in a
factory repair of the Master.
Содержание NetLinx Studio
Страница 40: ...Working with Projects 28 NetLinx Studio Instruction Manual...
Страница 148: ...Communication Settings 136 NetLinx Studio Instruction Manual...
Страница 160: ...Working with Online Devices 148 NetLinx Studio Instruction Manual...
Страница 178: ...File Transfer Operations 166 NetLinx Studio Instruction Manual...
Страница 208: ...Tools Menu Options 196 NetLinx Studio Instruction Manual...
Страница 229: ...Setting Program Preferences 217 NetLinx Studio Instruction Manual...