Building and Debugging Source Code
115
NetLinx Studio - Instruction Manual
Troubleshooting Debugging
NetLinx Debugger Not Stopping On a Breakpoint
Symptoms
- A breakpoint is set on a line of code, but the code does not stop execution on this line. The line of code in
question contains a SEND_COMMAND, SEND_STRING, or SEND_LEVEL.
Cause
- The debugger will not stop on a line of code that sends a command, string, or level because of a device declared
as an integer instead of a DEVICE:PORT:SYSTEM (D:P:S) structure.
Example:
DEFINE_DEVICE
VCR = 2
TP = 128
DEFINE_EVENT
BUTTON_EVENT[TP,101]
{
PUSH:
{
SEND_COMMAND VCR," 'SP', 9" //The debugger will not stop if you put a breakpoint here
}
}
Resolution
- Declare devices using the full D:P:S structure. In fact, you should always do this in NetLinx.
Example:
DEFINE_DEVICE
VCR = 2:1:0
TP = 128:1:0
DEFINE_EVENT
BUTTON_EVENT[TP,101]
{
PUSH:
{
SEND_COMMAND VCR," 'SP', 9" //The debugger will now stop if you put a breakpoint here
}
}
NetLinx Master Error - DEVICE_ID Error
When calling
DEVICE_ID
, this run time error can occur:
CIpLibrary::DEVICE_ID - Error 1
This error is cause by passing a parameter that is not of type
DEV
to the
DEVICE_ID
keyword. This usually occurs when
converting Axcess code to NetLinx. To fix this error, try the following:
Look for all references to the
DEVICE_ID
function
Make sure the value passed to the function is of type
DEV
. If this appears inside a
DEFINE_CALL
or
DEFINE_FUNCTION
and a parameter is passed to the
DEVICE_ID
function, make sure that parameter is of
type
DEV
.
Debug Option Disabled For Axcess Code File
Symptom
- After compiling and downloading an Axcess code file, the
Start Debugging
option (in the Debug menu) is
disabled.
Cause
- The code was created as an Axcess file, but was compiled as a NetLinx file.
Resolution
:
1.
Select the file in the Project Navigator window (Workspace tab), and right-click to open the Source Code File
Context Menu.
2.
Select
File Properties
to open the
File Properties
dialog.
3.
Change the
Compile As
selection to
Axcess
.
4.
Click
OK
to save the change and close the
File Properties
dialog.
5.
Recompile the file (as Axcess) and download.
Содержание NetLinx Studio
Страница 40: ...Working with Projects 28 NetLinx Studio Instruction Manual...
Страница 148: ...Communication Settings 136 NetLinx Studio Instruction Manual...
Страница 160: ...Working with Online Devices 148 NetLinx Studio Instruction Manual...
Страница 178: ...File Transfer Operations 166 NetLinx Studio Instruction Manual...
Страница 208: ...Tools Menu Options 196 NetLinx Studio Instruction Manual...
Страница 229: ...Setting Program Preferences 217 NetLinx Studio Instruction Manual...