Diagnostics Menu Options
170
NetLinx Studio - Instruction Manual
4.
Check or un-check the notification types as desired.
5.
Click
OK
to save your changes and return to the
NetLinx Device Notifications Options
dialog. The new notification
options are indicated (as ON) in the notifications list.
6.
In the
NetLinx Device Notifications Options
dialog, select
Enable Asynchronous Notifications
to enable/disable
NetLinx asynchronous notification messages being sent by the master controller. These are low-level strings of raw
data, used primarily for troubleshooting the NetLinx master. This option is intended for use in conjunction with
AMX Technical Support.
7.
Click
Done
to save changes and close the
NetLinx Device Notifications Options
dialog.
Break On String Options
Select
Diagnostics > Break On String Options
to open the
Break On String
Options
dialog (FIG. 250).
Both the
Notifications
and
Diagnostics
tabs of the Output Bar feature the ability to stop processing messages once a user-
defined string is matched with the current message from the NetLinx master. In this case, the connection remains active,
but the program stops processing the appropriate message stream.
The options in this dialog allow you to enable or disable Break On String for asynchronous notification or diagnostic
messages (or both). When the string specified in the text box(s) in this dialog are encountered, the specified message
type(s) are stopped. The items in this dialog include:
A very large amount of data may be generated if all options are enabled for every
device in a large System.
FIG. 250
Break On String Options dialog
Break On String dialog options
Asynchronous
Notification Messages:
Use this text box to specify the asynchronous notification message string that you want to break
execution on (maximum of 128 characters).
Diagnostics Messages: Use this text box to specify the diagnostic message string that you want to break execution on
(maximum of 128 characters).
Both message types have the following additional options:
•
Enable Break On String
- Select these check boxes to enable/disable Break On String, for the associated message
type.
•
Match Case
- This option makes the string(s) indicated case-sensitive (by default, this option is unchecked).
•
Scan Line Number and time Stamp
- This option causes the program to include the line number and time stamp as part
of the matching process.
Содержание NetLinx Studio
Страница 40: ...Working with Projects 28 NetLinx Studio Instruction Manual...
Страница 148: ...Communication Settings 136 NetLinx Studio Instruction Manual...
Страница 160: ...Working with Online Devices 148 NetLinx Studio Instruction Manual...
Страница 178: ...File Transfer Operations 166 NetLinx Studio Instruction Manual...
Страница 208: ...Tools Menu Options 196 NetLinx Studio Instruction Manual...
Страница 229: ...Setting Program Preferences 217 NetLinx Studio Instruction Manual...