6
Operating in CI Mode
Other Reagent Gases
7000/7010 Series TQ GC/MS Operating Manual
133
Other Reagent Gases
This section describes the use of isobutane or ammonia as the reagent gas. You
should be familiar with operating the CI-equipped 7000/7010
Series
TQ
GC/MS
with methane reagent gas before attempting to use other reagent gases.
Changing the reagent gas from methane to either isobutane or ammonia
changes the chemistry of the ionization process and yields different ions. The
principal CI reactions encountered are described in general in the
7000/7010 Triple Quadrupole GC/MS Concepts Guide
. If you are not experienced
with CI, we suggest reviewing that material before you proceed.
Isobutane CI
Isobutane (C
4
H
10
) is commonly used for CI when less fragmentation is desired
in the CI spectrum. This is because the proton affinity of isobutane is higher than
that of methane; hence less energy is transferred in the ionization reaction.
Addition and proton transfer are the ionization mechanisms most often
associated with isobutane. The sample itself influences which mechanism
dominates.
CAUTION
Do not use nitrous oxide as a reagent gas. It radically shortens the life span of
the filament.
Содержание 7010 Series
Страница 1: ...Agilent 7000 7010 Series Triple Quadrupole Operating Manual ...
Страница 12: ...12 7000 7010 Series TQ GC MS Operating Manual To Install a CI Source Filament 240 ...
Страница 128: ...5 Operating in EI Mode To Save a Method on the 7890 GC 128 7000 7010 Series TQ GC MS Operating Manual ...
Страница 204: ...7 General Maintenance To Close the Rear Analyzer Chamber 204 7000 7010 Series TQ GC MS Operating Manual ...
Страница 241: ......
Страница 242: ...www agilent com Agilent Technologies Inc 2019 First edition January 2019 G7003 90050 G7003 90050 ...